English
Language : 

DRV5023-Q1_16 Datasheet, PDF (5/28 Pages) Texas Instruments – Automotive Digital-Switch Hall Effect Sensor
www.ti.com
DRV5023-Q1
SLIS163C – DECEMBER 2014 – REVISED FEBRUARY 2016
6.5 Electrical Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
POWER SUPPLIES (VCC)
VCC
VCC operating voltage
ICC
Operating supply current
ton
Power-on time
OPEN DRAIN OUTPUT (OUT)
VCC = 2.7 to 38 V, TA = 25°C
VCC
=
2.7
to
38
V,
TA
=
TA,
(1)
MAX
rDS(on)
FET on-resistance
Ilkg(off)
Off-state leakage current
PROTECTION CIRCUITS
VCC = 3.3 V, IO = 10 mA, TA = 25°C
VCC = 3.3 V, IO = 10 mA, TA = 125°C
Output Hi-Z
VCCR
IOCP
Reverse supply voltage
Overcurrent protection level
OUT shorted VCC
(1) TA, MAX is 125°C for Q Grade 1 devices and 150°C for E Grade 0 devices (see )
MIN TYP
2.7
2.7
3
35
22
36
–22
15
30
MAX UNIT
38 V
mA
3.5
50 µs
Ω
50
1 µA
V
45 mA
6.6 Switching Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
OPEN DRAIN OUTPUT (OUT)
td
Output delay time
tr
Output rise time (10% to 90%)
tf
Output fall time (90% to 10%)
B = BRP – 10 mT to BOP + 10 mT in 1 µs
R1 = 1 kΩ, CO = 50 pF, VCC = 3.3 V
R1 = 1 kΩ, CO = 50 pF, VCC = 3.3 V
MIN TYP MAX UNIT
13
25
µs
200
ns
31
ns
6.7 Magnetic Characteristics
over operating free-air temperature range (unless otherwise noted)
PARAMETER
ƒBW Bandwidth(2)
DRV5023FA, DRV5023FI: 3.5 / 2 mT
TEST CONDITIONS
MIN TYP
20
30
BOP Operate point (see Figure 12)
BRP Release point (see Figure 12)
Bhys Hysteresis; Bhys= (BOP – BRP)
BO
Magnetic offset, BO = (BOP + BRP) / 2
DRV5023AJ: 6.9 / 3.2 mT
1.5
3.5
0.5
2
1.5
2.7
BOP Operate point (see Figure 12)
BRP Release point (see Figure 12)
Bhys Hysteresis; Bhys= (BOP – BRP)
BO
Magnetic offset, BO = (BOP + BRP) / 2
DRV5023BI: 14.5 / 6 mT
3
6.9
1
3.2
3.7
5
BOP Operate point (see Figure 12)
BRP Release point (see Figure 12)
Bhys Hysteresis; Bhys = (BOP – BRP)(3)
BO
Magnetic offset, BO = (BOP + BRP) / 2
6 14.5
3
6
8.5
10.3
(1) 1 mT = 10 Gauss
(2) Bandwidth describes the fastest changing magnetic field that can be detected and translated to the output.
(3) |BOP| is always greater than |BRP|.
MAX
UNIT (1)
kHz
6 mT
4 mT
mT
mT
12 mT
5 mT
mT
mT
24 mT
9 mT
mT
mT
Copyright © 2014–2016, Texas Instruments Incorporated
Product Folder Links: DRV5023-Q1
Submit Documentation Feedback
5