English
Language : 

DRV120_15 Datasheet, PDF (5/23 Pages) Texas Instruments – Power-Saving Current Controlled Solenoid Driver
www.ti.com
DRV120
SLVSBG3B – JUNE 2012 – REVISED JULY 2015
6.5 Electrical Characteristics
VIN = 14 V, TA = –40°C to 105°C, over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
SUPPLY
Standby current
IQ
Quiescent current
EN = 0, VIN = 14 V
EN = 1, VIN = 14 V
100
300
CURRENT DRIVER
ROUT
fPWM
DMAX
DMIN
OUT to GND resistance
PWM frequency
Maximum PWM duty cycle
Minimum PWM duty cycle
tD
Start-up delay
CURRENT CONTROLLER, INTERNAL SETTINGS
IOUT = 200 mA
OSC = GND
Delay between EN going high until driver enabled(1),
fPWM = 20 kHz
1.7
15
20
100
9
25
IPEAK
Peak current
IHOLD
Hold current
CURRENT CONTROLLER, EXTERNAL SETTINGS
tKEEP (2)
Externally set keep time at peak current
IPEAK
Externally set peak current
IHOLD
Externally set hold current
fPWM
Externally set PWM frequency
LOGIC INPUT LEVELS (EN)
PEAK = GND
HOLD = GND
CKEEP = 1 µF
RPEAK = 50 kΩ
RPEAK = 200 kΩ
RHOLD = 50 kΩ
RHOLD = 200 kΩ
ROSC = 50 kΩ
ROSC = 200 kΩ
160
200
40
50
75
250
83
100
33
60
20
VIL
Input low level
VIH
Input high level
REN
Input pullup resistance
LOGIC OUTPUT LEVELS (STATUS)
1.65
350
500
VOL
Output low level
IIL
Output leakage current
UNDERVOLTAGE LOCKOUT
Pulldown activated, ISTATUS = 2 mA
Pulldown deactivated, V(STATUS) = 5 V
VUVLO
Undervoltage lockout threshold
4.6
THERMAL SHUTDOWN
TTSD
Junction temperature shutdown
threshold
160
TTSU
Junction temperature start-up threshold
140
MAX
150
400
2.5
25
50
240
60
1.3
0.3
1
(1) Logic HIGH between 4 V and 7 V. Note: absolute maximum voltage rating is 7 V.
(2) Either internal or external tKEEP time setting is selected to be activated during manufacturing of production version of DRV120.
UNIT
µA
Ω
kHz
%
%
µs
mA
mA
ms
mA
mA
kHz
V
V
kΩ
V
µA
V
°C
°C
Copyright © 2012–2015, Texas Instruments Incorporated
Product Folder Links: DRV120
Submit Documentation Feedback
5