English
Language : 

BQ34210-Q1 Datasheet, PDF (5/19 Pages) Texas Instruments – Automotive 1-Series Cell System-Side CEDV Fuel Gauge for Rarely Discharged Batteries
www.ti.com
bq34210-Q1
SLUSCG1 – AUGUST 2017
Digital Input and Output DC Characteristics (continued)
TA = –40°C to 85°C, typical values at TA = 30°C and VREGIN = 3.6 V (unless otherwise noted)(Force Note1)(1)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
CIN (1)
Input capacitance(2)(3)
5
Ilkg
Input Leakage Current(2)(3)
1
(3) TS
UNIT
pF
μA
6.7 LDO Regulator, Wake-up, and Auto-Shutdown DC Characteristics
TA = –40°C to 85°C, typical values at TA = 30°C and VREGIN = 3.6 V (unless otherwise noted)(Force Note1)(1)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VREGIN
VREG18
UVLOIT+
Battery and regulator input
Regulator output voltage
VREGIN undervoltage lock-out
LDO wake-up rising threshold
2.45
1.85
2
4.5
V
V
V
UVLOIT–
VREGIN undervoltage lock-out
LDO auto-shutdown falling threshold
1.95
V
VWU+ (1)
ALERT (input) LDO Wake-up rising LDO Wake-up from SHUTDOWN
edge threshold(2)
mode
1.2
V
tALERT
Minimum ALERT high time after
VWU+ to initiate Wake up
1
ms
(1) Specified by design. Not production tested.
(2) If the device is commanded to SHUTDOWN via I2C with VREGIN > UVLOIT+, a wake-up rising edge trigger is required on ALERT.
6.8 LDO Regulator, Wake-up, and Auto-Shutdown AC Characteristics
TA = –40°C to 85°C, typical values at TA = 30°C and VREGIN = 3.6 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
tSHDN (1)
SHUTDOWN entry time
Time delay from SHUTDOWN
command to LDO output disable.
tSHUP (1)
tREG18 (1)
SHUTDOWN ALERT low time
Initial REG18 output delay
tWUREG18(1) Wake-up REG18 output delay
Minimum low time of ALERT (input)
in SHUTDOWN before WAKEUP
Time delay from rising edge of
ALERT (input) to nominal REG18
output.
10
13
8
Time delay from rising edge of
tPUCD
Power-up communication delay(2) REGIN to NORMAL mode (includes
250
firmware initialization time).
(1) Specified by design. Not production tested.
(2) tPUCD indicates when communication can begin. Measurements are not valid for up to 1 second after any reset.
MAX
250
UNIT
ms
μs
ms
ms
ms
6.9 ADC (Temperature and Cell Measurement) Characteristics
TA = –40°C to 85°C; typical values at TA = 30°C and VREGIN = 3.6 V (unless otherwise noted) (Force Note1)
PARAMETER
TEST CONDITIONS
MIN
TYP
VIN(REGIN) REGIN pin voltage measurement
range
2.45
tADC_CONV Conversion time
125
Effective resolution
15
MAX
4.5
UNIT
V
ms
bits
6.10 Integrating ADC (Coulomb Counter) Characteristics
TA = –40°C to 85°C; typical values at TA = 30°C and VREGIN = 3.6 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
VSRCM
Input voltage range of SRN, SRP
pins
VSS
TYP
MAX
VREGIN +
100 mV
UNIT
V
Copyright © 2017, Texas Instruments Incorporated
Product Folder Links: bq34210-Q1
Submit Documentation Feedback
5