English
Language : 

BQ29200_16 Datasheet, PDF (5/24 Pages) Texas Instruments – Voltage Protection with Automatic Cell Balance
www.ti.com
bq29200, bq29209
SLUSA52C – SEPTEMBER 2010 – REVISED MARCH 2016
7.2 ESD Ratings
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
Charged-device model (CDM), per JEDEC specification JESD22-
C101 (2)
VALUE
±2000
±500
UNIT
V
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process. Manufacturing with
less than 500-V HBM is possible with the necessary precautions.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process. Manufacturing with
less than 250-V CDM is possible with the necessary precautions.
7.3 Recommended Operating Conditions
Supply voltage, VDD
Input voltage range
VC2–VC1, VC1–GND
Delay time capacitance, td(CD)
CCD (See Figure 9.)
Voltage monitor filter resistance RIN (See Figure 9.)
Voltage monitor filter capacitance CIN (See Figure 9.)
Supply voltage filter resistance RVD (See Figure 9.)
Supply voltage filter capacitance CVD (See Figure 9.)
Cell balance resistance
RCB (See Figure 9 and Protection (OUT) Timing.)
Operating ambient temperature range, TA
MIN NOM MAX UNIT
4
10 V
0
5V
0.1
µF
100
1K
Ω
0.01
0.1
µF
100
1K Ω
0.1
µF
100
4.7K Ω
–40
110 °C
7.4 Thermal Information
THERMAL METRIC(1)
bq2920x
DRB
UNIT
8 PINS
RθJA
RθJC(top)
RθJB
ψJT
ψJB
RθJC(bot)
Junction-to-ambient thermal resistance
Junction-to-case(top) thermal resistance
Junction-to-board thermal resistance
Junction-to-top characterization parameter
Junction-to-board characterization parameter
Junction-to-case(bottom) thermal resistance
50.5
°C/W
25.1
°C/W
19.3
°C/W
0.7
°C/W
18.9
°C/W
5.2
°C/W
(1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application
report, SPRA953.
7.5 Electrical Characteristics
Typical values stated where TA = 25°C and VDD = 7.2 V. Minimum and maximum values stated where TA = –40°C to 110°C
and VDD = 4 V to 10 V (unless otherwise noted).
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
VPROTECT
Overvoltage bq29209
detection
voltage
bq29200
4.3
V
4.35
VHYS
Overvoltage detection
hysteresis
200 300 400 mV
VOA
Overvoltage detection
accuracy
TA = 25°C
–10
10 mV
VOA_DRIFT
XDELAY
Overvoltage threshold
temperature drift
Overvoltage delay time
scale factor
TA = 0°C to 60°C
TA = –40°C to 110°C
TA = 0°C to 60°C
Note: Does not include external capacitor variation.
TA = –40°C to 110°C
Note: Does not include external capacitor variation.
–0.4
0.4
mV°/C
–0.6
0.6
6
9 12
s/µF
5.5
9 13.5
Copyright © 2010–2016, Texas Instruments Incorporated
Product Folder Links: bq29200 bq29209
Submit Documentation Feedback
5