English
Language : 

TLC59282_15 Datasheet, PDF (4/24 Pages) Texas Instruments – 16-Channel, Constant-Current LED Driver with 4-Channel Grouped Delay
TLC59282
SBVS152C – DECEMBER 2010 – REVISED OCTOBER 2011
www.ti.com
ELECTRICAL CHARACTERISTICS
At VCC = 3 V to 5.5 V and TA = –40°C to +85°C. Typical values at VCC = 3.3 V and TA = +25°C, unless otherwise noted.
TLC59282
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
VOH
VOL
IIN
ICC0
ICC1
ICC2
ICC3
IOLC
IOLKG
ΔIOLC0
High-level output voltage
Low-level output voltage
Input current
Supply current (VCC)
Constant output current
Output leakage current
Constant-current error
(channel-to-channel) (1)
IOH = –1 mA at SOUT
IOL = 1 mA at SOUT
VIN = VCC or GND at SIN and SCLK
SIN/SCLK/LAT = low, BLANK = high, VOUTn = 1 V,
RIREF = open
SIN/SCLK/LAT = low, BLANK = high, VOUTn = 1 V,
RIREF = 3 kΩ (IOUT = 16.8 mA target)
All OUTn = ON, SIN/SCLK/LAT/BLANK = low,
VOUTn = 1 V, RIREF = 3 kΩ
All OUTn = ON, SIN/SCLK/LAT/BLANK = low,
VOUTn = 1 V, RIREF = 1.5 kΩ (IOUT = 33.6mA target)
All OUTn = ON, VOUTn = VOUTfix = 1 V, RIREF = 1.5 kΩ
at OUT0 to OUT15 (see Figure 6), TA = +25°C
OUTn = OFF, VOUTn = VOUTfix = 17 V, BLANK = high,
RIREF = 1.5 kΩ at OUT0 to OUT15 (see Figure 6)
All OUTn = ON, VOUTn = VOUTfix = 1 V, RIREF = 1.5 kΩ
at OUT0 to OUT15
VCC – 0.4
–1
32.1
0.1
4.5
7
16
33.7
±0.6
VCC
V
0.4
V
1
μA
1
mA
6
mA
15
mA
34
mA
35.3
mA
0.1
μA
±2
%
ΔIOLC1
ΔIOLC2
ΔIOLC3
VIREF
RPUP
RPDWN
Constant-current error
(device-to-device) (2)
Line regulation(3)
Load regulation(4)
Reference voltage output
Pull-up resistor
Pull-down resistor
All OUTn = ON, VOUTn = VOUTfix = 1 V, RIREF = 1.5 kΩ
at OUT0 to OUT15, TA = +25°C
All OUTn = ON, VOUTn = VOUTfix = 1 V, RIREF = 1.5 kΩ
at OUT0 to OUT15, VCC = 3 V to 5.5 V
All OUTn = ON, VOUTn = 1 V to 3V, VOUTfix = 1 V,
RIREF = 1.5 kΩ
RIREF = 1.5 kΩ, TA = +25°C
BLANK
LAT
±1
±0.5
±1
1.18
1.205
250
500
250
500
±3
%
±1
%/V
±3
%/V
1.23
V
750
kΩ
750
kΩ
(1) The deviation of each output from the average of OUT0–OUT15 constant-current. Deviation is calculated by the formula:
D (%) =
IOUTn
- 1 ´ 100
(IOUT0 + IOUT1 + ... + IOUT14 + IOUT15)
16
.
(2) The deviation of the OUT0–OUT15 constant-current average from the ideal constant-current value.
Deviation is calculated by the following formula:
D (%) =
(IOUT0 + IOUT1 + ... IOUT14 + IOUT15)
- (Ideal Output Current)
16
Ideal Output Current
´ 100
Ideal current is calculated by the formula:
IOUT(IDEAL) = 41.9 ´
1.205
RIREF
(3) Line regulation is calculated by this equation:
D (%/V) =
(IOUTn at VCC = 5.5 V) - (IOUTn at VCC = 3 V)
(IOUTn at VCC = 3 V)
100
´
5.5 V - 3 V
(4) Load regulation is calculated by the equation:
D (%/V) =
(IOUTn at VOUTn = 3 V) - (IOUTn at VOUTn = 1 V)
(IOUTn at VOUTn = 1 V)
100
´
3V-1V
4