English
Language : 

TLC2932_15 Datasheet, PDF (4/29 Pages) Texas Instruments – HIGH-PERFORMANCE PHASE-LOCKED LOOP
TLC2932
HIGH-PERFORMANCE PHASE-LOCKED LOOP
SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997
schematics
VCO block schematic
RBIAS
BIAS
VCO IN
Bias
Control
VCO
Output
1/2
M
U VCO OUT
X
VCO INHIBIT
PFD block schematic
Charge Pump
VDD
SELECT
FIN – A
Detector
PFD OUT
FIN – B
PFD INHIBIT
absolute maximum ratings†
Supply voltage (each supply), VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage range (each input), VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VDD + 0.5 V
Input current (each input), II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output current (each output), IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Continuous total power dissipation, at (or below) TA = 25°C (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . 700 mW
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 20°C to 75°C
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values are with respect to network GND.
2. For operation above 25°C free-air temperature, derate linearly at the rate of 5.6 mW/°C.
4