6.2 ESD Ratings
V(ESD) Electrostatic discharge
Human-body model (HBM), per ANSI/ESDA/JEDEC JS-001(1)
VALUE
±1500
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
UNIT
V
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)(1)
Supply Voltage
Junction Temperature Range
LMC6482M
MIN
MAX
UNIT
3
15.5
V
–55
125
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
6.4 Thermal Information
THERMAL METRIC(1)
LMC6482-MIL LMC6482-MIL LMC6482-MIL
D (SOIC) DGK (VSSOP) P (PDIP)
UNIT
8 PINS
8 PINS
8 PINS
RθJA
Junction-to-ambient thermal resistance
155
194
90
°C/W
(1) For more information about traditional and new thermal metrics, see the IC Package Thermal Metrics application report, SPRA953.
6.5 Electrical Characteristics for V+ = 5 V
Unless otherwise specified, all limits specified for TJ = 25°C, V+ = 5 V, V− = 0 V, VCM = VO = V+/2 and RL > 1 M.
PARAMETER
TEST CONDITIONS
TJ = 25°C
MIN TYP(2) MAX(3)
At Temperature Extremes(1)
MIN TYP(2) MAX(3)
DC Electrical Characteristics
VOS
Input Offset
Voltage
0.11
3
3.8
TCVOS
IB
IOS
Input Offset
Voltage
Average Drift
Input Current
Input Offset
Current
See (4)
See (4)
1
0.02
10
0.01
5
CIN
Common-Mode
3
Input
Capacitance
RIN
Input
10
Resistance
CMRR
Common-Mode
Rejection Ratio
0 V ≤ VCM ≤ 15 V
V+ = 15 V
0 V ≤ VCM ≤ 5 V
V+ = 5 V
65
82
60
65
82
60
Positive Power
+PSRR Supply
Rejection Ratio
5 V ≤ V+ ≤ 15 V,
V− = 0 V
VO = 2.5 V
65
82
60
−PSRR
Negative Power
Supply
Rejection Ratio
−5 V ≤ V− ≤ −15 V, V+ = 0 V
VO = −2.5 V
65
82
60
UNIT
mV
μV/°C
pA
pA
pF
TeraΩ
dB
dB
dB
(1) See Recommended Operating Conditions for operating temperature ranges.
(2) Typical Values represent the most likely parametric norm.
(3) All limits are specified by testing or statistical analysis.
(4) Ensured limits are dictated by tester limitations and not device performance. Actual performance is reflected in the typical value.