English
Language : 

HD3SS2522 Datasheet, PDF (4/25 Pages) Texas Instruments – USB Type-C SS MUX
HD3SS2522
SLLSEM6B – APRIL 2015 – REVISED AUGUST 2015
www.ti.com
PIN
NAME
NO.
CC_OUT
11
CC_SEL_IN
12
CC_SEL_OUT
19
CC_OEn_IN
9
CC_OEn_OUT /
VconnEnPol
32
CC1
CC2
GND
GPIO1
GPIO2
37
35
33 , 39, 53
28
29
IMODE1
26
IMODE2
27
MODE_LED
NC
RST
RSVD
SS_OEn_IN
15
1, 24, 49, 50, 51,
54, 55, 56
30
10, 25, 31, 36, 38
8
SS_OEn_OUT /
VBUSEnPol
34
SS_SEL_IN
SS_SEL_OUT
VBUS_EN
VBUS_FAULT#
VCC
VCONN_FAULT#
VCTRL1
7
20
21
16
4 , 13, 14, 40, 52
17
22
VCTRL2
23
Pin Functions (continued)
I/O
DESCRIPTION
I/O Selected CC signal as output - connect to CC_IN pin
I
CC Signal select pin input – Connect to CC_SEL_OUT
O CC Signal select pin output – Connect to CC_SEL_IN
I
Active Low CC MUX Enable input – connect to CC_OEn_OUT
Active Low CC MUX Enable output – connect to CC_OEn. The pin is also sampled
I/O
upon reset to set the polarity of the VCTRL1 and VCTRL2.
0 = VCTRL1/2 polarity is active high.
1 = VCTRL1/2 polarity is active low.
I/O USB Type-C configuration channel for position 1
I/O USB Type-C configuration channel for position 2
G Ground
I/O GPIO or SCL for FW update
I/O GPIO or SDA for FW update
IMODE1
IMODE2
Current Mode
Low
Low
Default
I
Low
High
Mid (1.5 A)
High
Low
Reserved
High
High
High (3A)
O High when UFP attach detected
Not connected
I
CC Controller Reset
I/O Reserved
I
Active Low SS MUX Enable input – connect to SS_OEn_OUT
Active Low SS MUX Enable output – connect to SS_OEn_IN. The pin is also sampled
I/O
upon reset to set the polarity of the VBUS_EN.
0 = VBUS_EN polarity is active high.
1 = VBUS_EN polarity is active low.
I
SS Port select pin input – Connect to SS_SEL_OUT
O SS Port select pin output – Connect to SS_SEL_IN
O
Polarity programmable via VBUSEnPol pin (pin 34). Driven low or high when UFP
attach is detected.
I
VBUS Fault signal in from VBUS Power switch. Active low.
P 3.3V Power
I
VCONN Fault signal in from VCONN switches. Active low.
O
Polarity programmable via VconnEnPol pin (pin 32). Driven low or high when active
cable is detected.
O
Polarity programmable via VconnEnPol pin (pin 32). Driven low or high when active
cable is detected.
4