9.3.3.2
Table 9-4. 16-Bit Timer With Prescaler Configurations (continued)
Prescale
#Clock (T c)a
Max Time
00000001
2
2.6214
00000010
3
3.9322
------------
--
--
11111101
254
332.9229
11111110
255
334.2336
11111111
256
335.5443
a. Tc is the clock period.
Units
mS
mS
--
mS
mS
mS
16-Bit Input Edge Count Mode
Note:
For rising-edge detection, the input signal must be High for at least two system clock periods
following the rising edge. Similarly, for falling-edge detection, the input signal must be Low
for at least two system clock periods following the falling edge. Based on this criteria, the
maximum input frequency for edge detection is 1/4 of the system frequency.
Note: The prescaler is not available in 16-Bit Input Edge Count mode.
In Edge Count mode, the timer is configured as a down-counter capable of capturing three types
of events: rising edge, falling edge, or both. To place the timer in Edge Count mode, the TnCMR bit
of the GPTMTnMR register must be set to 0. The type of edge that the timer counts is determined
by the TnEVENT fields of the GPTMCTL register. During initialization, the GPTM Timern Match
(GPTMTnMATCHR) register is configured so that the difference between the value in the
GPTMTnILR register and the GPTMTnMATCHR register equals the number of edge events that
must be counted.
When software writes the TnEN bit in the GPTM Control (GPTMCTL) register, the timer is enabled
for event capture. Each input event on the CCP pin decrements the counter by 1 until the event count
matches GPTMTnMATCHR. When the counts match, the GPTM asserts the CnMRIS bit in the
GPTMRIS register (and the CnMMIS bit, if the interrupt is not masked).
The counter is then reloaded using the value in GPTMTnILR, and stopped since the GPTM
automatically clears the TnEN bit in the GPTMCTL register. Once the event count has been reached,
all further events are ignored until TnEN is re-enabled by software.
Figure 9-2 on page 334 shows how input edge count mode works. In this case, the timer start value
is set to GPTMTnILR =0x000A and the match value is set to GPTMTnMATCHR =0x0006 so that
four edge events are counted. The counter is configured to detect both edges of the input signal.
Note that the last two edges are not counted since the timer automatically clears the TnEN bit after
the current count matches the value in the GPTMTnMATCHR register.
July 15, 2014
333
Texas Instruments-Production Data