English
Language : 

BQ40Z50-R1 Datasheet, PDF (33/55 Pages) Texas Instruments – Li-Ion Battery Pack Manager
www.ti.com
bq40z50-R1
SLUSCB3 – JULY 2015
Figure 26. Differential Filter
9.2.2.2.2 Power Supply Decoupling and PBI
The bq40z50-R1 has an internal LDO that is internally compensated and does not require an external decoupling
capacitor.
The PBI pin is used as a power supply backup input pin providing power during brief transient power outages. A
standard 2.2-µF ceramic capacitor is connected from the PBI pin to ground as shown in Figure 27.
Figure 27. Power Supply Decoupling
9.2.2.2.3 System Present
The System Present signal is used to inform the gas gauge whether the pack is installed into or removed from
the system. In the host system, this pin is grounded. The PRES pin of the bq40z50-R1 is occasionally sampled
to test for system present. To save power, an internal pullup is provided by the gas gauge during a brief 4-μs
sampling pulse once per second. A resistor can be used to pull the signal low and the resistance must be 20 kΩ
or lower to insure that the test pulse is lower than the VIL limit. The pull-up current source is typically 10 µA to
20 µA.
Copyright © 2015, Texas Instruments Incorporated
Product Folder Links: bq40z50-R1
Submit Documentation Feedback
33