English
Language : 

CD74ACT86-EP Datasheet, PDF (3/11 Pages) Texas Instruments – QUADRUPLE 2-INPUT EXCLUSIVE-OR GATE
www.ti.com
CD74ACT86-EP
QUADRUPLE 2-INPUT EXCLUSIVE-OR GATE
SCHS357 – MARCH 2006
Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VOH
VOL
II
ICC
∆ICC (2)
Ci
TEST CONDITIONS
VI = VIH or VIL
VI = VIH or VIL
VI = VCC or GND
VI = VCC or GND,
VI = VCC – 2.1 V
IOH = –50 µA
IOH = –24 mA
IOH = –50 mA(1)
IOL = 50 µA
IOL = 24 mA
IOL = 50 mA(1)
IO = 0
VCC
4.5 V
5.5 V
4.5 V
5.5 V
5.5 V
5.5 V
4.5 V to 5.5 V
TA = 25°C
MIN MAX
4.4
3.94
3.85
0.1
0.36
1.65
±0.1
4
2.4
10
–55°C to
125°C
MIN MAX
4.4
3.7
3.85
0.1
0.5
1.65
±1
80
3
10
UNIT
V
V
µA
µA
mA
pF
(1) Test one output at a time, not exceeding 1-s duration. Measurement is made by forcing indicated current and measuring voltage to
minimize power dissipation. Test verifies a minimum 50-Ω transmission-line drive capability at 85°C and 75-Ω transmission-line drive
capability at 125°C.
(2) Additional quiescent supply current per input pin, TTL inputs high, 1 unit load
ACT INPUT LOAD TABLE(1)
INPUT
All
UNIT LOAD
0.48
(1) Unit load is ∆ICC limit specified in
electrical characteristics table
(e.g., 2.4 mA at 25°C).
Switching Characteristics
over recommended operating free-air temperature range, VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
–55°C to
125°C
MIN MAX
tPLH
tPHL
A or B
3.7 14.6
Y
3.7 14.6
UNIT
ns
Operating Characteristics
VCC = 5 V, TA = 25°C
Cpd
Power dissipation capacitance
PARAMETER
TYP UNIT
57 pF
Submit Documentation Feedback
3