English
Language : 

AMC1204 Datasheet, PDF (3/29 Pages) Texas Instruments – 20MHz, Second-Order, Isolated Delta-Sigma Modulator for Current-Shunt Measurement
AMC1204
www.ti.com
REGULATORY INFORMATION
VDE/IEC
Certified according to IEC 60747-5-2
File number: 40016131
CSA
Approved under CSA component
acceptance notice
File number: 2350550
SBAS512A – APRIL 2011 – REVISED APRIL 2011
UL
Recognized under 1577 component
recognition program
File number: E181974
IEC SAFETY LIMITING VALUES
Safety limiting intends to prevent potential damage to the isolation barrier upon failure of input or output (I/O) circuitry. A
failure of the I/O circuitry can allow low resistance to ground or the supply and, without current limiting, dissipate sufficient
power to overheat the die and damage the isolation barrier, potentially leading to secondary system failures.
The safety-limiting constraint is the operating virtual junction temperature range specified in the Absolute Maximum Ratings
table. The power dissipation and junction-to-air thermal impedance of the device installed in the application hardware
determine the junction temperature. The assumed junction-to-air thermal resistance in the Thermal Information table is that of
a device installed in the JESD51-3, Low Effective Thermal Conductivity Test Board for Leaded Surface Mount Packages and
is conservative. The power is the recommended maximum input voltage times the current. The junction temperature is then
the ambient temperature plus the power times the junction-to-air thermal resistance.
PARAMETER
TEST CONDITIONS
MIN TYP
MAX UNIT
IS Safety input, output, or supply current
TC Maximum case temperature
θJA = +78.5°C/W, VI = 5.5V,
TJ = +150°C, TA = +25°C
10 mA
+150 °C
IEC 61000-4-5 RATINGS
PARAMETER
VIOSM Surge immunity
TEST CONDITIONS
1.2/50μs voltage surge and 8/20μs current surge
VALUE
±4000
UNIT
V
IEC 60664-1 RATINGS
PARAMETER
Basic isolation group
Installation classification
TEST CONDITIONS
Material group
Rated mains voltage ≤ 150VRMS
Rated mains voltage < 300VRMS
Rated mains voltage < 400VRMS
Rated mains voltage < 600VRMS
SPECIFICATION
II
I-IV
I-IV
I-III
I-III
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): AMC1204
Submit Documentation Feedback
3