Pollution Degree:
Pollution Degree 1âNo pollution, or only dry, nonconductive pollution occurs. The pollution has no influence on
device performance.
Pollution Degree 2âNormally, only nonconductive pollution occurs. However, a temporary conductivity caused
by condensation is to be expected.
Pollution Degree 3âConductive pollution, or dry nonconductive pollution that becomes conductive because of
condensation, occurs. Condensation is to be expected.
Pollution Degree 4âContinuous conductivity occurs as a result of conductive dust, rain, or other wet conditions.
Installation Category:
Overvoltage CategoryâThis section is directed at insulation coordination by identifying the transient overvoltages
that may occur, and by assigning four different levels as indicated in IEC 60664.
1. Signal Level: Special equipment or parts of equipment.
2. Local Level: Portable equipment, etc.
3. Distribution Level: Fixed installation.
4. Primary Supply Level: Overhead lines, cable systems.
Each category should be subject to smaller transients than the previous category.
Copyright © 2011, Texas Instruments Incorporated
Product Folder Link(s): AMC1204