English
Language : 

HD3SS460 Datasheet, PDF (24/34 Pages) Texas Instruments – 4 x 6 Channels USB Type-C Alternate Mode MUX
HD3SS460
SLLSEM7B – JANUARY 2015 – REVISED JUNE 2016
www.ti.com
Layout Guidelines (continued)
• Decoupling capacitors should be placed next to each power terminal on the HD3SS460. Care should be
taken to minimize the stub length of the trace connecting the capacitor to the power pin.
• Avoid sharing vias between multiple decoupling capacitors.
• Place vias as close as possible to the decoupling capacitor solder pad.
• Widen VCC/GND planes to reduce effect of static and dynamic IR drop.
• The VBUS traces/planes must be wide enough to carry maximum of 2 A current.
11.2 Layout Example
Figure 20, Figure 21, and Figure 22 illustrate some guidelines for layout. Actual layout should be optimized for
various factors such as board geometry, connector type, and application.
Figure 20. USB Type C Connector to HD3SS460 Signal Routing
Figure 21. Dual SMT Mid-Mount Type C Connector Layout Example Zoom-in
24
Submit Documentation Feedback
Product Folder Links: HD3SS460
Copyright © 2015–2016, Texas Instruments Incorporated