English
Language : 

OPA333_17 Datasheet, PDF (22/42 Pages) Texas Instruments – 1.8-V, microPower, CMOS Operational Amplifiers, Zero-Drift Series
OPA333, OPA2333
SBOS351E – MARCH 2006 – REVISED DECEMBER 2015
www.ti.com
R1
100 kW
RA
R2
100 kW
LL
R3
100 kW
LA
+VS
1/2
OPA2333
+VS
1/2
OPA2333
+VS
1/2
OPA2333
C1
47 pF
R6
100 kW
R7
100 kW
R8
100 kW
Wilson
VCENTRAL
(RA + LA + LL) / 3
R5
390 kW
R4
100 kW
RL
+VS
1/2
OPA2333
Inverted
VCM
R9
20 kW
+VS
1/2
OPA2333
+VS
C2
0.64 mF
R10
1 MW
1/2 VS
R11
1 MW
fLPF = 150 Hz
C4
1.06 nF
GTOT = 1 kV/V
+VS
3
7 GINA = 5
6
INA321(1)
2
1
4
5
C3
1 mF
dc
ac
+VS
R12
5 kW
R13
318 kW
1/2
OPA2333
R14
1 MW
+VS
OPA333
VOUT
GOPA = 200
fHPF = 0.5 Hz
(provides ac signal coupling)
1/2 VS
VS = +2.7 V to +5.5 V
BW = 0.5 Hz to 150 Hz
fO = 0.5 Hz
(1) Other instrumentation amplifiers can be used, such as the INA326, which has lower noise, but higher quiescent
current.
Figure 33. Single-Supply, Very Low Power, ECG Circuit
9 Power Supply Recommendations
The OPAx333 is specified for operation from 1.8 V to 5.5 V (±0.9 V to ±2.75 V); many specifications apply from
–40°C to 125°C. The Typical Characteristics presents parameters that can exhibit significant variance with regard
to operating voltage or temperature.
CAUTION
Supply voltages larger than 7 V can permanently damage the device (see the Absolute
Maximum Ratings).
TI recommends placing 0.1-μF bypass capacitors close to the power-supply pins to reduce errors coupling in
from noisy or high-impedance power supplies. For more detailed information on bypass capacitor placement,
refer to the Layout section.
22
Submit Documentation Feedback
Copyright © 2006–2015, Texas Instruments Incorporated
Product Folder Links: OPA333 OPA2333