English
Language : 

MSP430G2X32_14 Datasheet, PDF (20/61 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430G2x32
MSP430G2x02
SLAS723H – DECEMBER 2010 – REVISED MAY 2013
www.ti.com
Schmitt-Trigger Inputs – Ports Px(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
VIT+ Positive-going input threshold voltage
TEST CONDITIONS
VCC
MIN TYP
MAX UNIT
0.45 VCC
3V
1.35
0.75 VCC
V
2.25
VIT– Negative-going input threshold voltage
0.25 VCC
3V
0.75
0.55 VCC
V
1.65
Vhys Input voltage hysteresis (VIT+ – VIT–)
3V
RPull Pullup/pulldown resistor
For pullup: VIN = VSS
For pulldown: VIN = VCC
3V
CI
Input capacitance
VIN = VSS or VCC
0.3
20
35
5
1V
50 kΩ
pF
(1) An external signal sets the interrupt flag every time the minimum interrupt pulse width t(int) is met. It may be set even with trigger signals
shorter than t(int).
Leakage Current – Ports Px
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
Ilkg(Px.x)
PARAMETER
High-impedance leakage current
TEST CONDITIONS
(1) (2)
VCC
MIN
3V
MAX UNIT
±50 nA
(1) The leakage current is measured with VSS or VCC applied to the corresponding pin(s), unless otherwise noted.
(2) The leakage of the digital port pins is measured individually. The port pin is selected for input, and the pullup/pulldown resistor is
disabled.
Outputs – Ports Px
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER
VOH High-level output voltage
VOL Low-level output voltage
TEST CONDITIONS
I(OHmax) = –6 mA (1)
I(OLmax) = 6 mA (1)
VCC
MIN
TYP MAX UNIT
3V
VCC – 0.3
V
3V
VSS + 0.3
V
(1) The maximum total current, I(OHmax) and I(OLmax), for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop
specified.
Output Frequency – Ports Px
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
fPx.y
fPort_CLK
PARAMETER
Port output frequency (with load)
Clock output frequency
TEST CONDITIONS
Px.y, CL = 20 pF, RL = 1 kΩ(1) (2)
Px.y, CL = 20 pF(2)
VCC
MIN TYP
3V
12
3V
16
MAX
UNIT
MHz
MHz
(1) A resistive divider with two 0.5-kΩ resistors between VCC and VSS is used as load. The output is connected to the center tap of the
divider.
(2) The output voltage reaches at least 10% and 90% VCC at the specified toggle frequency.
20
Submit Documentation Feedback
Copyright © 2010–2013, Texas Instruments Incorporated