DRV201_15 Datasheet, PDF (18/29 Pages) Texas Instruments – DRV201 Voice Coil Motor Driver for Camera Auto Focus | |||
|
◁ |
DRV201
SLVSB25C â AUGUST 2011 â REVISED JUNE 2015
www.ti.com
FIELD NAME
VCM_FREQ[7:0]
Table 7. Bit Definitions
BIT DEFINITION
VCM mechanical ringing frequency for the ringing compensation can be selected with the below
formula. The formula gives the VCM_FREQ[7:0] register value in decimal which should be rounded to
the nearest integer.
19200
VCM _ FREQ = 383 -
Fres
(1)
Default VCM mechanical ringing frequency is 76.4 Hz.
19200
VCM _ FREQ = 383 -
= 131.69 Ã 132 Ã '1000 0011'
76.4
(2)
18
Submit Documentation Feedback
Product Folder Links: DRV201
Copyright © 2011â2015, Texas Instruments Incorporated
|
▷ |