English
Language : 

MSP430P325A Datasheet, PDF (14/35 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
MSP430C32x, MSP430P325A
MIXED SIGNAL MICROCONTROLLER
SLAS219B − MARCH 1999 − REVISED MARCH 2000
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
supply current into AVCC+DVCC excluding external current, fsystem = 1 MHz
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
I(AM)
Active mode, A/D conversion in
power-down
C32x
P325A
TA = −40°C to 85°C,
TA = −40°C to 85°C,
TA = −40°C to 85°C,
TA = −40°C to 85°C,
VCC = 3 V
VCC = 5 V
VCC = 3 V
VCC = 5 V
400 500
800 900
μA
500 550
950 1050
I(CPUOff) Low power mode, (LPM0, LPM1)
C32x
P325A
TA = −40°C to 85°C,
TA = −40°C to 85°C,
TA = −40°C to 85°C,
TA = −40°C to 85°C,
VCC = 3 V
VCC = 5 V
VCC = 3 V
VCC = 5 V
50
70
100 130
μA
50
70
100 130
I(LPM2)
Low power mode, (LPM2)
TA = −40°C to 85°C,
TA = −40°C to 85°C,
VCC = 3 V
VCC = 5 V
6
12
μA
15
25
TA = −40°C
1.5 2.4
TA = 25°C
VCC = 3 V
1.3
2
I(LPM3)
Low power mode, (LPM3)
TA = 85°C
TA = −40°C
1.6 2.8
μA
5.2
7
TA = 25°C
VCC = 5 V
4.2 6.5
TA = 85°C
4
7
TA = −40°C
0.1 0.8
I(LPM4)
Low power mode, (LPM4)
TA = 25°C
VCC = 3 V/5 V
0.1 0.8 μA
TA = 85°C
0.4 1.3
NOTE: All inputs are tied to 0 V or VCC. Outputs do not source or sink any current. The current consumption in LPM2, LPM3 and LPM4 are
measured with active Basic Timer1 (ACLK selected) and LCD Module (f(LCD)=1024 Hz, 4 MUX).
current consumption of active mode versus system frequency
IAM = IAM[1 MHz] × fsystem [MHz]
current consumption of active mode versus supply voltage
IAM = IAM[3 V] + 200 μA/V × (VCC−3 V)
Schmitt-trigger inputs Port 0, P0.x Timer/Port, CIN, TP 0.5
PARAMETER
VIT+
Positive-going input threshold voltage
VIT−
Negative-going input threshold voltage
Vhys
Hysteresis (VIT+−VIT−)
TEST CONDITIONS
VCC = 3 V
VCC = 5 V
VCC = 3 V
VCC = 5 V
VCC = 3 V
VCC = 5 V
MIN TYP MAX UNIT
1.2
2.1
2.3
3.4
0.5
1.35
V
1.4
2.3
0.3
1
0.6
1.4
14
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265