TLE202X-EP Datasheet, PDF (12/46 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS | |||
|
◁ |
TLE202x-EP, TLE202xA-EP
EXCALIBUR HIGH-SPEED LOW-POWER PRECISION
OPERATIONAL AMPLIFIERS
SGLS235Dâ FEBRUARY 2004 â REVISED SEPTEMBER 2010
TLE2024 electrical characteristics at specified free-air temperature, VCC = ±15 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TLE2024-EP
TLE2024A-EP
TAâ
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
1000
1200
750
μV
950
αVIO
Temperature coefficient
of input offset voltage
Full range
2
2
μV/°C
Input offset voltage
long-term drift
(see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.006
0.006
μV/mo
IIO
Input offset current
25°C
Full range
0.6
6
10
0.2
6
nA
10
IIB
Input bias current
25°C
Full range
50 70
90
45 70
nA
90
VICR
Common-mode input
voltage range
RS = 50 Ω
â15 â15.3
â15 â15.3
25°C
to
to
to
to
13.5 14
13.5 14
V
â15
â15
Full range
to
to
13.2
13.2
VOM +
VOM â
Maximum positive peak
output voltage swing
Maximum negative peak
output voltage swing
RL = 10 kΩ
25°C
13.8 14.1
13.8 14.2
V
Full range 13.7
13.7
25°C â13.7 â14.1
â13.7 â14.1
V
Full range â13.6
â13.6
Large-signal differential
AVD
voltage amplification
VO = ±10 V,
25°C
0.4
2
RL = 10 kΩ Full range
0.4
0.8
4
0.8
V/μV
Common-mode rejection
CMRR ratio
VIC = VICRmin,
RS = 50 Ω
25°C
Full range
92 102
88
94 105
90
dB
kSVR
Supply-voltage rejection
ratio (ÎVCC ± /ÎVIO)
VCC ± = ± 2.5 V to ±15 V
25°C
Full range
98 112
93
100 115
95
dB
ICC
ÎICC
Supply current
Supply current change
over operating
temperature range
VO = 0,
No load
25°C
Full range
Full range
1050 1400
1400
85
1050 1400
μA
1400
85
μA
â Full range is â40°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
12
⢠POST OFFICE BOX 655303 DALLAS, TEXAS 75265
|
▷ |