English
Language : 

TLE202X-EP Datasheet, PDF (10/46 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE202x-EP, TLE202xA-EP
EXCALIBUR HIGH-SPEED LOW-POWER PRECISION
OPERATIONAL AMPLIFIERS
SGLS235D− FEBRUARY 2004 − REVISED SEPTEMBER 2010
TLE2022 electrical characteristics at specified free-air temperature, VCC = ±15 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TLE2022-EP
TLE2022A-EP
TA†
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
150 500
700
120 300
450 μV
αVIO
Temperature coefficient
of input offset voltage
Full range
2
2
μV/°C
Input offset voltage
long-term drift
(see Note 4)
IIO
Input offset current
VIC = 0,
RS = 50 Ω
25°C
25°C
Full range
0.006
0.5
6
10
0.006
0.4
μV/mo
6
nA
10
IIB
Input bias current
25°C
Full range
35 70
90
33 70
nA
90
VICR
Common-mode input
voltage range
RS = 50 Ω
VOM +
VOM −
Maximum positive peak
output voltage swing
Maximum negative peak
output voltage swing
RL = 10 kΩ
−15 −15.3
−15 −15.3
25°C
to
to
to
to
13.5 14
13.5 14
V
−15
−15
Full range
to
to
13.2
13.2
25°C
14 14.3
14 14.3
V
Full range 13.8
13.8
25°C −13.7 −14.1
−13.7 −14.1
V
Full range −13.6
−13.6
Large-signal differential
AVD
voltage amplification
VO = ±10 V,
25°C
0.8
4
RL = 10 kΩ Full range
0.8
1
7
1
V/μV
Common-mode rejection
CMRR ratio
VIC = VICRmin,
25°C
RS = 50 Ω Full range
95 106
91
97 109
dB
93
kSVR
Supply-voltage rejection
ratio (ΔVCC ± /ΔVIO)
VCC ± = ±2.5 V to ±15 V
25°C
100 115
Full range 95
103 118
98
dB
ICC
ΔICC
Supply current
Supply current change
over operating
temperature range
VO = 0,
No load
25°C
Full range
Full range
550 700
700
60
550 700
μA
700
60
μA
† Full range is −40°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
10
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265