English
Language : 

TLE202X-EP Datasheet, PDF (11/46 Pages) Texas Instruments – EXCALIBUR HIGH-SPEED LOW-POWER PRECISION OPERATIONAL AMPLIFIERS
TLE202x-EP, TLE202xA-EP
EXCALIBUR HIGH-SPEED LOW-POWER PRECISION
OPERATIONAL AMPLIFIERS
SGLS235D− FEBRUARY 2004 − REVISED SEPTEMBER 2010
TLE2024 electrical characteristics at specified free-air temperature, VCC = 5 V (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
TLE2024-EP
TLE2024A-EP
TA†
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
1100
1300
850
μV
1050
αVIO
Temperature coefficient
of input offset voltage
Full range
2
2
μV/°C
Input offset voltage
long-term drift
(see Note 4)
VIC = 0,
RS = 50 Ω
25°C
0.005
0.005
μV/mo
IIO
Input offset current
25°C
Full range
0.6
6
10
0.5
6
nA
10
IIB
Input bias current
25°C
Full range
45 70
90
40 70
nA
90
VICR
Common-mode input
voltage range
RS = 50 Ω
0 −0.3
0 −0.3
25°C
to
to
to
to
3.5
4
3.5
4
V
0
0
Full range
to
to
3.2
3.2
VOH
High-level output voltage
RL = 10 kΩ
VOL
Low-level output voltage
25°C
3.9 4.2
3.9 4.2
V
Full range 3.7
3.7
25°C
Full range
0.7 0.8
0.95
0.7 0.8
V
0.95
Large-signal differential
25°C
0.2 1.5
AVD
voltage amplification
VO = 1.4 V to 4 V, RL = 10 kΩ Full range
0.1
0.3 1.5
0.1
V/μV
Common-mode rejection
25°C
80 90
CMRR ratio
VIC = VICRmin,
RS = 50 Ω Full range
80
82 92
82
dB
kSVR
Supply-voltage rejection
ratio (ΔVCC± /ΔVIO)
VCC ± = ±2.5 V to ±15 V
25°C
Full range
98 112
93
100 115
95
dB
ICC
ΔICC
Supply current
Supply current change
over operating
temperature range
VO = 0,
No load
25°C
Full range
Full range
800 1200
1200
50
800 1200
μA
1200
50
μA
† Full range is −40°C to 125°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
11