6.21 Timing Requirements
TA = –40°C to 85°C, 2.4 V < VREG25 < 2.6 V; typical values at TA = 25°C and VREG25 = 2.5 V (unless otherwise noted)
MIN
NOM
MAX
I2C-Compatible Interface Timing Characteristics (see Figure 1)
tR
SCL or SDA rise time
tF
SCL or SDA fall time
tw(H)
SCL pulse width (high)
tw(L)
SCL pulse width (low)
tsu(STA)
Setup for repeated start
td(STA)
Start to first falling edge of SCL
tsu(DAT)
Data setup time
th(DAT)
Data hold time
tsu(STOP)
Setup time for stop
tBUF
Bus free time between stop and start
fSCL
Clock frequency
HDQ Communication Timing Characteristics (see Figure 2)
300
300
600
1.3
600
600
100
0
600
66
400
t(CYCH)
t(CYCD)
t(HW1)
t(DW1)
t(HW0)
t(DW0)
t(RSPS)
t(B)
t(BR)
t(RST)
t(RISE)
Cycle time, host to fuel gauge
Cycle time, fuel gauge to host
Host sends 1 to fuel gauge
Fuel gauge sends 1 to host
Host sends 0 to fuel gauge
Fuel gauge sends 0 to host
Response time, fuel gauge to host
Break time
Break recovery time
HDQ reset
HDQ line rise time to logic 1 (1.2 V)
190
190
205
250
0.5
50
32
50
86
145
80
145
190
950
190
40
1.8
2.2
950
UNIT
ns
ns
ns
μs
ns
ns
ns
ns
ns
μs
kHz
μs
μs
μs
μs
μs
μs
μs
μs
μs
s
ns
tSU(STA)
tw(H)
tw(L)
tf
tr
t(BUF)
SCL
SDA
td(STA)
tf
tr
th(DAT)
tsu(DAT)
tsu(STOP)
REPEATED
START
STOP
START
Figure 1. I2C-Compatible Interface Timing Diagrams