English
Language : 

TLC2272 Datasheet, PDF (11/63 Pages) Texas Instruments – Advanced LinCMOS Rail-to-Rail Operational Amplifiers
www.ti.com
TLC2272, TLC2272A, TLC2272M, TLC2272AM
TLC2274, TLC2274A, TLC2274M, TLC2274AM
SLOS190H – FEBRUARY 1997 – REVISED MARCH 2016
6.8 TLC2274 and TLC2274A Electrical Characteristics VDD± = ±5 V
at specified free-air temperature, VDD± = ±5 V; TA = 25°C, unless otherwise noted.
PARAMETER
TEST CONDITIONS
VIO
Input offset voltage
VIC = 0 V, VO = 0 V,
RS = 50 Ω
TLC2274
TLC2274A
TLC2274
TLC2274A
TA = 25°C
Full Range(1)
αVIO
Temperature coefficient of
input offset voltage
VIC = 0 V, VO = 0 V, RS = 50 Ω
Input offset voltage long-term drift(2) VIC = 0 V, VO = 0 V, RS = 50 Ω
All level parts TA = 25°C
IIO
Input offset current
VIC = 0 V, VO = 0 V,
RS = 50 Ω
C level part
I level part
Q level part
TA = 0°C to 80°C
TA = –40°C to 85°C
TA = –40°C to 125°C
M level part
TA = –55°C to 125°C
All level parts TA = 25°C
IIB
Input bias current
VIC = 0 V, VO = 0 V,
RS = 50 Ω
C level part
I level part
Q level part
TA = 0°C to 80°C
TA = –40°C to 85°C
TA = –40°C to 125°C
M level part
TA = –55°C to 125°C
VICR Common-mode input voltage
RS = 50 Ω; |VIO | ≤ 5 mV
TA = 25°C
Full Range(1)
VOM+
Maximum positive peak
output voltage
IO = −20 μA
IO = −200 μA
IO = −1 mA
TA = 25°C
Full Range(1)
TA = 25°C
Full Range(1)
VOM-
Maximum negative peak
output voltage
VIC = 0 V
IO = 50 μA
IO = 500 μA
IO = 5 mA
TA = 25°C
Full Range(1)
TA = 25°C
Full Range(1)
AVD
Large-signal differential
voltage amplification
C level part
VO = ±4 V; RL = 10 kΩ
I level part
Q level part
VO = ±4 V; RL = 1 MΩ
M level part
TA = 25°C
TA = 0°C to 80°C
TA = 25°C
TA = –40°C to 85°C
TA = 25°C
TA = –40°C to 125°C
TA = 25°C
TA = –55°C to 125°C
rid
Differential input resistance
ri
Common-mode input resistance
ci
Common-mode input capacitance
zo
Closed-loop output impedance
CMRR Common-mode rejection ratio
f = 10 kHz, P package
f = 1 MHz, AV = 10
VIC = –5 V to 2.7 V,
VO = 0 V, RS = 50 Ω
TA = 25°C
Full Range(1)
kSVR
Supply-voltage rejection ratio
(ΔVDD / ΔVIO)
VDD+ = 2.2 V to ±8 V,
VIC = 0 V, no load
TA = 25°C
Full Range(1)
IDD
Supply currrent
VO = 0 V, no load
TA = 25°C
Full Range(1)
MIN
–5.3
–5
4.85
4.85
4.25
4.25
–4.85
–4.85
–3.5
–3.5
25
25
25
25
20
20
20
20
75
75
80
80
TYP
300
300
2
0.002
0.5
1
0
0
4.99
4.93
4.65
MAX
2500
950
3000
1500
UNIT
µV
μV/°C
μV/mo
60
100
150 pA
800
800
60
100
150 pA
800
800
4
V
3.5
V
–4.99
–4.91
V
–4.1
50
50
50
V/mV
50
300
1012
Ω
1012
Ω
8
pF
130
Ω
80
dB
95
dB
4.8
6
mA
6
(1) TA = –55°C to 125°C.
(2) Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated to
TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
Copyright © 1997–2016, Texas Instruments Incorporated
Submit Documentation Feedback
11