English
Language : 

TIOS101 Datasheet, PDF (11/26 Pages) Texas Instruments – Digital Sensor Output Drivers with Integrated Surge Protection
www.ti.com
TIOS101
SLLSEV6 – JULY 2017
8.3.4 Fault Reporting (NFAULT)
NFAULT is driven low if either a current fault condition is detected, die temperature has exceeded T(WRN) or
supply has dropped below the UVLO threshold. NFAULT returns to high-impedance as soon as all three fault
conditions clear.
Output at Hi-Z
CUR_OK=Z
Driver = OFF
LDO = ON
EN*
T > TWRN
Normal
Operation
CUR_OK = Z
Driver = ON
LDO = ON
Thermal
Warning
CUR_OK = Z
TMP_OK = L
Driver= EN/EN*
LDO= ON
EN
EN*
T < TWRN &
T >TWRN
Out at IO(LIM) and T < TWRN
Current
Fault
CUR_OK = L
Driver = OFF
LDO= ON
Thermal
Shutdown
CUR_OK = Z
TMP_OK = L
Driver = OFF
LDO = ON
Current
Fault Recovery
CUR_OK = L
Driver = ON for tsc
LDO= ON
NFAULT = [CUR_OK && PWR_OK && TMP_OK]
Figure 10. Device State Diagram
Copyright © 2017, Texas Instruments Incorporated
Product Folder Links: TIOS101
Submit Documentation Feedback
11