DRV5023_16 Datasheet, PDF (11/28 Pages) Texas Instruments – Digital-Switch Hall Effect Sensor
www.ti.com
DRV5023
SLIS151E – MAY 2014 – REVISED FEBRUARY 2016
Feature Description (continued)
7.3.3 Power-On Time
After applying VCC to the DRV5023 device, ton must elapse before the OUT pin is valid. During the power-up
sequence, the output is Hi-Z. A pulse as shown in Figure 13 and Figure 14 occurs at the end of ton. This pulse
can allow the host processor to determine when the DRV5023 output is valid after startup. In Case 1 (Figure 13)
and Case 2 (Figure 14), the output is defined assuming a constant magnetic field B > BOP and B < BRP.
VCC
t (s)
B (mT)
BOP
BRP
t (s)
OUT
Valid Output
t (s)
ton
Figure 13. Case 1: Power On When B > BOP
VCC
t (s)
B (mT)
BOP
BRP
t (s)
OUT
Valid Output
t (s)
ton
Figure 14. Case 2: Power On When B < BRP
Copyright © 2014–2016, Texas Instruments Incorporated
Product Folder Links: DRV5023
Submit Documentation Feedback
11