English
Language : 

TM4C1290NCPDT Datasheet, PDF (1062/1628 Pages) Texas Instruments – Tiva Microcontroller
Analog-to-Digital Converter (ADC)
Bit/Field
8
7:4
3
2
1
0
Name
DMAMASK0
reserved
MASK3
MASK2
MASK1
MASK0
Type
RW
Reset
0
Description
SS0 DMA Interrupt Mask
Value Description
0 The status of Sample Sequencer 0 DMA does not affect the
SS0 interrupt status.
1 The raw interrupt signal from Sample Sequencer 0 DMA
(ADCRIS register DMAINR0 bit) is sent to the interrupt controller.
RO
0
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
RW
0
SS3 Interrupt Mask
Value Description
0 The status of Sample Sequencer 3 does not affect the SS3
interrupt status.
1 The raw interrupt signal from Sample Sequencer 3 (ADCRIS
register INR3 bit) is sent to the interrupt controller.
RW
0
SS2 Interrupt Mask
Value Description
0 The status of Sample Sequencer 2 does not affect the SS2
interrupt status.
1 The raw interrupt signal from Sample Sequencer 2 (ADCRIS
register INR2 bit) is sent to the interrupt controller.
RW
0
SS1 Interrupt Mask
Value Description
0 The status of Sample Sequencer 1 does not affect the SS1
interrupt status.
1 The raw interrupt signal from Sample Sequencer 1 (ADCRIS
register INR1 bit) is sent to the interrupt controller.
RW
0
SS0 Interrupt Mask
Value Description
0 The status of Sample Sequencer 0 does not affect the SS0
interrupt status.
1 The raw interrupt signal from Sample Sequencer 0 (ADCRIS
register INR0 bit) is sent to the interrupt controller.
1062
Texas Instruments-Production Data
June 18, 2014