English
Language : 

TC244 Datasheet, PDF (10/19 Pages) Texas Instruments – 786- × 488-PIXEL CCD IMAGE SENSOR
TC244
786- × 488-PIXEL CCD IMAGE SENSOR
SOCS016B – NOVEMBER 1989 – REVISED DECEMBER 1991
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range for ADB, CDB, IDB (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 V to 15 V
Input voltage range for ABG, IAG, SAG, SRG, TRG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –15 V to 15 V
Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 30°C to 85°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 30°C to 85°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to the substrate terminal.
recommended operating conditions
MIN NOM MAX UNIT
Supply voltage, ADB
11
12
13 V
Substrate bias voltage
0
V
High level
1.5
2 2.5
IAG
Intermediate level§
– 5.7
Low level
– 11
–9
SRG1, SRG2, SRG3
High level
Low level
1.5
2 2.5
–11
–9
Input voltage, VI‡
ABG
High level
Intermediate level§
2
4
– 2.3
6
V
Low level
–7.5
–7 – 6.5
SAG
High level
Low level
1.5
2 2.5
– 11
–9
TRG
High level
Low level
1.5
2 2.5
– 11
–9
IAG, SAG
3.58
Clock frequency, fclock
SRG1, SRG2, SRG3, TRG
ABG
4.77 MHz
2
Capacitive load
OUT1 (R), OUT2 (G), OUT3 (B)
6 pF
Operating free-air temperature, TA
– 10
45 °C
‡ The algebraic convention, in which the least-positive (most negative) value is designated minimum, is used in this data sheet for clock voltage
levels.
§ Adjustment is required for optimal performance.
2-10
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265