English
Language : 

TS3DV416_09 Datasheet, PDF (9/18 Pages) Texas Instruments – 4-CHANNEL DIFFERENTIAL 8:16 MULTIPLEXER SWITCH FOR DVI/HDMI APPLICATIONS
www.ti.com
TS3DV416
4-CHANNEL DIFFERENTIAL 8:16 MULTIPLEXER SWITCH
FOR DVI/HDMI APPLICATIONS
SCDS198C – OCTOBER 2005 – REVISED MAY 2006
PARAMETER MEASUREMENT INFORMATION
(Enable and Disable Times)
Input Generator
50 Ω
VG1
Input Generator
50 Ω
VG2
VIN
50 Ω
VI
50 Ω
VDD
DUT
TEST CIRCUIT
VO
CL
(see Note A)
RL
RL
2 × VDD
S1
Open
GND
TEST
tPLZ/tPZL
tPHZ/tPZH
VDD
3.3 V ± 0.3 V
3.3 V ± 0.3 V
S1
2 × VDD
GND
RL
200 Ω
200 Ω
VI
GND
VDD
CL
10 pF
10 pF
V∆
0.3 V
0.3 V
Output Control
(VIN)
Output
Waveform 1
S1 at 2 y VDD tPZL
(see Note B)
tPZH
Output
Waveform 2
S1 at GND
(see Note B)
1.25 V
VDD/2
VDD/2
1.25 V
tPLZ
2.5 V
0V
VOH
VOL +0.3 V
tPHZ
VOH −0.3 V
VOL
VOH
VOL
VOLTAGE WAVEFORMS
ENABLE AND DISABLE TIMES
NOTES: A. CL includes probe and jig capacitance.
B. Waveform 1 is for an output with internal conditions such that the output is low, except when disabled by the output control.
Waveform 2 is for an output with internal conditions such that the output is high, except when disabled by the output control.
C. All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr ≤ 2.5 ns, tf ≤ 2.5 ns.
D. The outputs are measured one at a time, with one transition per measurement.
E. tPLZ and tPHZ are the same as tdis.
F. tPZL and tPZH are the same as ten.
Figure 4. Test Circuit and Voltage Waveforms
Submit Documentation Feedback
9