English
Language : 

TLC27M4 Datasheet, PDF (9/37 Pages) Texas Instruments – LinCMOSE PRECISION QUAD OPERATIONAL AMPLIFIERS
TLC27M4, TLC27M4A, TLC27M4B, TLC27M4Y, TLC27M9
LinCMOS™ PRECISION QUAD OPERATIONAL AMPLIFIERS
SLOS093C – OCTOBER 1987 – REVISED MAY 1999
electrical characteristics at specified free-air temperature, VDD = 10 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC27M4I
TLC27M4AI
TA†
TLC27M4BI
UNIT
TLC27M9I
MIN TYP MAX
VIO Input offset voltage
TLC27M4I
TLC27M4AI
TLC27M4BI
TLC27M9I
VO = 1.4 V,
RS = 50 Ω,
VO = 1.4 V,
RS = 50 Ω,
VO = 1.4 V,
RS = 50 Ω,
VO = 1.4 V,
RS = 50 Ω,
VIC = 0,
RL = 100 kΩ
VIC = 0,
RL = 100 kΩ
VIC = 0,
RL = 100 kΩ
VIC = 0,
RL = 100 kΩ
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
1.1
10
13
mV
0.9
5
7
260 2000
3500
µV
220 1200
2900
αVIO
Average temperature coefficient of input
offset voltage
25°C to
85°C
2.1
µV/°C
IIO
Input offset current (see Note 4)
VO = 5 V,
VIC = 5 V
25°C
85°C
0.1
pA
26 1000
IIB
Input bias current (see Note 4)
VO = 5 V,
VIC = 5 V
25°C
85°C
0.7
pA
220 2000
VICR
Common-mode input
voltage range (see Note 5)
– 0.2 – 0.3
25°C
to
to
V
9 9.2
– 0.2
Full range
to
V
8.5
25°C
8 8.7
VOH High-level output voltage
VID = 100 mV,
RL = 100 kΩ
– 40°C
7.8 8.7
V
85°C
7.8 8.7
25°C
0
50
VOL Low-level output voltage
VID = – 100 mV,
IOL = 0
– 40°C
85°C
0
50 mV
0
50
AVD
Large-signal differential
voltage amplification
VO = 1 V to 6 V,
RL = 100 kΩ
25°C
– 40°C
85°C
25 275
15 390
15 220
V/mV
25°C
65
94
CMRR Common-mode rejection ratio
VIC = VICRmin
– 40°C
60
93
dB
85°C
60
94
kSVR
Supply-voltage rejection ratio
(∆VDD /∆VIO)
25°C
70
93
VDD = 5 V to 10 V, VO = 1.4 V
– 40°C
60
91
dB
85°C
60
94
IDD Supply current (four amplifiers)
VO = 5 V,
No load
VIC = 5 V,
25°C
– 40°C
85°C
570 1200
900 1800 µA
410 1040
† Full range is – 40°C to 85°C.
NOTES: 4. The typical values of input bias current and input offset current below 5 pA were determined mathematically.
5. This range also applies to each input individually.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265