English
Language : 

TLC27M4 Datasheet, PDF (8/37 Pages) Texas Instruments – LinCMOSE PRECISION QUAD OPERATIONAL AMPLIFIERS
TLC27M4, TLC27M4A, TLC27M4B, TLC27M4Y, TLC27M9
LinCMOS™ PRECISION QUAD OPERATIONAL AMPLIFIERS
SLOS093C – OCTOBER 1987 – REVISED MAY 1999
electrical characteristics at specified free-air temperature, VDD = 5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TLC27M4I
TLC27M4AI
TA†
TLC27M4BI
UNIT
TLC27M9I
MIN TYP MAX
VIO Input offset voltage
TLC27M4I
TLC27M4AI
TLC27M4BI
TLC27M9I
VO = 1.4 V,
RS = 50 Ω,
VO = 1.4 V,
RS = 50 Ω,
VO = 1.4 V,
RS = 50 Ω,
VO = 1.4 V,
RS = 50 Ω,
VIC = 0,
RL = 100 kΩ
VIC = 0,
RL = 100 kΩ
VIC = 0,
RL = 100 kΩ
VIC = 0,
RL = 100 kΩ
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
1.1
10
13
mV
0.9
5
6.5
250 2000
3000
µV
210 900
2000
αVIO
Average temperature coefficient of input
offset voltage
25°C to
85°C
1.7
µV/°C
IIO
Input offset current (see Note 4)
VO = 2.5 V,
VIC = 2.5 V
25°C
85°C
0.1
pA
24 1000
IIB
Input bias current (see Note 4)
VO = 2.5 V,
VIC = 2.5 V
25°C
85°C
0.6
pA
200 2000
VICR
Common-mode input voltage range
(see Note 5)
– 0.2 – 0.3
25°C
to
to
V
4 4.2
– 0.2
Full range
to
V
3.5
25°C
3.2 3.9
VOH High-level output voltage
VID = 100 mV,
RL = 100 kΩ
– 40°C
3 3.9
V
85°C
3
4
25°C
0
50
VOL Low-level output voltage
VID = –100 mV,
IOL = 0
– 40°C
85°C
0
50 mV
0
50
AVD
Large-signal differential
voltage amplification
VO = 0.25 V to 2 V, RL = 100 kΩ
25°C
– 40°C
85°C
25 170
15 270
15 130
V/mV
25°C
65
91
CMRR Common-mode rejection ratio
VIC = VICRmin
– 40°C
60
90
dB
85°C
60
90
kSVR
Supply-voltage rejection ratio
(∆VDD /∆VIO)
25°C
70
93
VDD = 5 V to 10 V, VO = 1.4 V
– 40°C
60
91
dB
85°C
60
94
IDD Supply current (four amplifiers)
VO = 2.5 V,
No load
VIC = 2.5 V,
25°C
– 40°C
85°C
420 1120
630 1600 µA
320 800
† Full range is – 40°C to 85°C.
NOTES: 4. The typical values of input bias current and input offset current below 5 pA were determined mathematically.
5. This range also applies to each input individually.
8
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265