English
Language : 

SN74AVC16646 Datasheet, PDF (9/18 Pages) Texas Instruments – 16-BIT BUS TRANSCEIVER AND REGISTER WITH 3-STATE OUTPUTS
www.ti.com
SN74AVC16646
16-BIT BUS TRANSCEIVER AND REGISTER
WITH 3-STATE OUTPUTS
SCES181F – DECEMBER 1998 – REVISED JUNE 2005
Electrical Characteristics
over recommended operating free-air temperature range (unless otherwise noted)
PARAMETER
VOH
VOL
II
Control inputs
Ioff
IOZ (2)
ICC
CLK inputs
Ci
Control inputs
Cio A or B ports
TEST CONDITIONS
IOHS = –100 µA
IOHS = –2 mA,
IOHS = –4 mA,
IOHS = –8 mA,
IOHS = –12 mA,
IOLS = 100 µA
IOLS = 2 mA,
IOLS = 4 mA,
IOLS = 8 mA,
IOLS = 12 mA,
VI = VCC or GND
VI or VO = 3.6 V
VO = VCC or GND,
VI = VCC or GND,
VIH = 0.91 V
VIH = 1.07 V
VIH = 1.7 V
VIH = 2 V
VIL = 0.49 V
VIL = 0.57 V
VIL = 0.7 V
VIL = 0.8 V
VI = VCC
IO = 0
VI = VCC or GND
VO = VCC or GND
VCC
1.2 V to 3.6 V
1.4 V
1.65 V
2.3 V
3V
1.2 V to 3.6 V
1.4 V
1.65 V
2.3 V
3V
3.6 V
0
3.6 V
3.6 V
2.5 V
3.3 V
2.5 V
3.3 V
2.5 V
3.3 V
MIN
VCC – 0.2
1.05
1.2
1.75
2.3
TYP (1)
3
3
3.5
3.5
8
8
MAX
0.2
0.4
0.45
0.55
0.7
±2.5
±10
±12.5
40
UNIT
V
V
µA
µA
µA
µA
pF
pF
(1) Typical values are measured at TA = 25°C.
(2) For I/O ports, the parameter IOZ includes the input leakage current.
Timing Requirements
over recommended operating free-air temperature range (unless otherwise noted) (see Figure 3 through Figure 6)
fclock
tw
tsu
th
Clock frequency
Pulse
duration
CLKAB or CLKBA
high or low
Setup time
A before CLKAB↑ or
B before CLKBA↑
Hold time
A after CLKAB↑ or
B after CLKBA↑
VCC = 1.2 V
MIN MAX
2.1
1.3
VCC = 1.5 V
± 0.1 V
MIN MAX
VCC = 1.8 V
± 0.15 V
MIN MAX
150
VCC = 2.5 V
± 0.2 V
MIN MAX
250
VCC = 3.3 V
± 0.3 V
MIN MAX
350
3.3
2
1.4
1.6
1.2
0.9
0.8
1
0.8
0.6
0.6
UNIT
MHz
ns
ns
ns
9