English
Language : 

LT1014 Datasheet, PDF (9/30 Pages) Texas Instruments – QUAD PRECISION OPERATIONAL AMPLIFIERS
LT1014, LT1014A, LT1014D
QUAD PRECISION OPERATIONAL AMPLIFIERS
SLOS039C – JULY 1989 – REVISED SEPTEMBER 1999
electrical characteristics at specified free-air temperature, VCC± = ±15 V, VIC = 0 (unless otherwise
noted)
PARAMETER
VIO
aVIO
IIO
IIB
Input offset
voltage
Temperature
coefficient of
input offset
voltage
Long-term drift
of input offset
voltage
Input offset
current
Input bias
current
TEST
CONDITIONS
RS = 50 Ω
TA†
25°C
Full range
Full range
25°C
25°C
Full range
25°C
Full range
VICR
Common-mode
input voltage
range
25°C
Full range
VOM
AVD
CMRR
Maximum peak
output voltage
swing
Large-signal
differential
voltage
amplification
Common-mode
rejection ratio
RL = 2 kΩ
VO = ±10 V,
RL = 600 Ω
VO = ±10 V,
RL = 2 kΩ
VIC = –15 V to
13.5 V
VIC = –14.9 V
to 13 V
25°C
Full range
25°C
25°C
Full range
25°C
Full range
kSVR
rid
Supply-voltage
rejection ratio
(∆VCC/∆VIO)
Channel
separation
Differential input
resistance
VCC± = ±2 V to
±18 V
VO = ±10 V,
RL = 2 kΩ
25°C
Full range
25°C
25°C
ric
Common-mode
input resistance
Supply current
ICC
per amplifier
† Full range is –55°C to 125°C.
‡ All typical values are at TA = 25°C.
25°C
25°C
Full range
LT1014M
MIN TYP‡ MAX
60 300
550
0.5 2.5
0.5
0.15 1.5
5
–12 –30
–45
–15 –15.3
to
to
13.5 13.8
–14.9
to 13
±12.5 ±14
±11.5
0.5
2
1.2
8
0.25
97 117
94
100 117
97
120 137
70 300
4
0.35 0.55
0.7
LT1014AM
MIN TYP‡ MAX
60 180
350
0.5
2
0.5
0.15 0.8
2.8
–12 –20
–30
–15 –15.3
to
to
13.5 13.8
–14.9
to 13
±13 ±14
±12
0.8 2.2
1.5
8
0.4
100 117
96
103 117
100
123 137
100 300
4
0.35 0.50
0.6
LT1014DM
MIN TYP‡ MAX
200 800
1000
UNIT
µV
0.5 2.5 µV/°C
0.5
µV/mo
0.15 1.5
nA
5
–12 –30
nA
–45
–15 –15.3
to
to
13.5 13.8
V
–14.9
to 13
±12.5 ±14
V
±11.5
0.5
2
1.2
8
0.25
97 117
94
V/µV
dB
100 117
dB
97
120 137
dB
70 300
MΩ
4
GΩ
0.35 0.55
mA
0.7
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
9