English
Language : 

LT1014 Datasheet, PDF (5/30 Pages) Texas Instruments – QUAD PRECISION OPERATIONAL AMPLIFIERS
LT1014, LT1014A, LT1014D
QUAD PRECISION OPERATIONAL AMPLIFIERS
SLOS039C – JULY 1989 – REVISED SEPTEMBER 1999
electrical characteristics at specified free-air temperature, VCC± = ±15 V, VIC = 0 (unless otherwise
noted)
PARAMETER
TEST CONDITIONS
VIO
aVIO
IIO
Input offset voltage
Temperature coeficient
of input offset voltage
Long-term drift
of input offset voltage
Input offset current
RS = 50 Ω
IIB
Input bias current
VICR
Common-mode
input voltage range
VOM
AVD
Maximum peak output
voltage swing
Large-signal differential
voltage amplification
RL = 2 kΩ
VO = ±10 V,
VO = ±10 V,
RL = 600 Ω
RL = 2 kΩ
CMRR
Common-mode
rejection ratio
kSVR
rid
Supply-voltage
rejection ratio
(∆VCC/∆VIO)
Channel separation
Differential
input resistance
VIC = –15 V to 13.5 V
VIC = –15 V to 13 V
VCC± = ±2 V to ±18 V
VO = ±10 V, RL = 2 kΩ
Common-mode
ric
input resistance
Supply current
ICC
per amplifier
† Full range is 0°C to 70°C.
‡ All typical values are at TA = 25°C.
TA†
25°C
Full range
Full range
LT1014C
MIN TYP‡ MAX
60 300
550
0.4 2.5
LT1014DC
MIN TYP‡ MAX
200 800
1000
UNIT
µV
0.7
5 µV/°C
25°C
0.5
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
25°C
Full range
25°C
Full range
25°C
0.15
–12
–15
to
13.5
–15
to 13
±12.5
±12
0.5
1.2
0.7
97
94
–15.3
to
13.8
±14
2
8
117
100 117
Full range
97
25°C
120 137
25°C
70 300
0.5
1.5
0.15
2.8
–30
–12
–38
–15 –15.3
to
to
13.5 13.8
–15
to 13
±12.5 ±14
±12
0.5
2
1.2
8
0.7
97 117
94
100 117
97
120 137
70 300
µV/mo
1.5
nA
2.8
–30
nA
–38
V
V
V/µV
dB
dB
dB
MΩ
25°C
25°C
Full range
4
0.35 0.55
0.6
4
GΩ
0.35 0.55
mA
0.6
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5