English
Language : 

LT1014 Datasheet, PDF (8/30 Pages) Texas Instruments – QUAD PRECISION OPERATIONAL AMPLIFIERS
LT1014, LT1014A, LT1014D
QUAD PRECISION OPERATIONAL AMPLIFIERS
SLOS039C – JULY 1989 – REVISED SEPTEMBER 1999
electrical characteristics at specified free-air temperature, VCC+ = 5 V, VCC– = 0, VO = 1.4 V, VIC = 0
(unless otherwise noted)
PARAMETER
VIO Input offset voltage
IIO
Input offset current
IIB
Input bias current
Common-mode
VICR input voltage range
VOM
Maximum peak
output voltage swing
AVD
Large-signal differential
voltage amplification
Supply current
ICC
per amplifier
† Full range is –40°C to 105°C.
TEST CONDITIONS
RS = 50 Ω
Output low, No load
Output low,
RL = 600 Ω to GND
Output low, Isink = 1 mA
Output high, No load
Output high,
RL = 600 Ω to GND
VO = 5 mV to 4 V,
RL = 500 Ω
TA†
25°C
Full range
25°C
Full range
25°C
Full range
25°C
Full range
25°C
25°C
Full range
25°C
25°C
25°C
Full range
25°C
25°C
Full range
LT1014I
MIN TYP MAX
90 450
570
0.2
2
6
–15 –50
–90
0 –0.3
to 3.5 to 3.8
0 to 3
15
25
5
10
13
220 350
4 4.4
3.4
4
3.2
1
0.3 0.5
0.55
LT1014DI
MIN TYP MAX
250 950
1200
0.2
2
6
–15 –50
–90
0 –0.3
to 3.5 to 3.8
0 to 3
15
25
5
10
13
220 350
4 4.4
3.4
4
3.2
1
0.3 0.5
0.55
UNIT
µV
nA
nA
V
mV
V
V/µV
mA
operating characteristics, VCC+ = ±15 V, VIC = 0, TA = 25°C
PARAMETER
TEST CONDITIONS
SR
Slew rate
Vn
Equivalent input noise voltage
f = 10 Hz
f = 1 kHz
VN(PP) Peak-to-peak equivalent input noise voltage
In
Equivalent input noise current
f = 0.1 Hz to 10 Hz
f = 10 Hz
MIN TYP MAX UNIT
0.2 0.4
V/µs
24
22
nV/√Hz
0.55
µV
0.07
pA/√Hz
8