BQ27510-G3 Datasheet, PDF (8/20 Pages) Texas Instruments – System-Side Impedance Track Fuel Gauge With Direct Battery Connection
bq27510-G3
SLUSAT1 – MARCH 2013
DATA COMMANDS
www.ti.com
STANDARD DATA COMMANDS
The bq27510-G3 fuel gauge uses a series of 2-byte standard commands to enable system reading and writing of
battery information. Each standard command has an associated command-code pair, as indicated in Table 1.
Because each command consists of two bytes of data, two consecutive I2C transmissions must be executed both
to initiate the command function, and to read or write the corresponding two bytes of data. Additional options for
transferring data are described in Section of COMMUNICATIONS. Standard commands are accessible in
NORMAL operation. Read and write permissions depend on the active access mode, SEALED or UNSEALED.
Additional details are found in the bq27510-G3 Technical Reference Manual.
NAME
Control( )
AtRate( )
AtRateTimeToEmpty( )
Temperature( )
Voltage( )
Flags( )
NominalAvailableCapacity( )
FullAvailableCapacity( )
RemainingCapacity( )
FullChargeCapacity( )
AverageCurrent( )
TimeToEmpty( )
StandbyCurrent( )
StandbyTimeToEmpty( )
StateOfHealth( )
CycleCount( )
StateOfCharge( )
InstantaneousCurrent( )
InternalTemperature( )
ResistanceScale( )
OperationConfiguration( )
DesignCapacity( )
Table 1. Standard Commands
COMMAND CODE
0x00 / 0x01
0x02 / 0x03
0x04 / 0x05
0x06 / 0x07
0x08 / 0x09
0x0a / 0x0b
0x0c / 0x0d
0x0e / 0x0f
0x10 / 0x11
0x12 / 0x13
0x14 / 0x15
0x16 / 0x17
0x18 / 0x19
0x1a/ 0x1b
0x1c / 0x1d
0x1e/ 0x1f
0x20/ 0x21
0x22 / 0x23
0x28 / 0x29
0x2a / 0x2b
0x2c/ 0x2d
0x2e / 0x2f
UNITS
N/A
mA
Minutes
0.1 K
mV
N/A
mAh
mAh
mAh
mAh
mA
Minutes
mA
Minutes
% / num
num
%
mA
0.1 K
N/A
mAh
SEALED
ACCESS
R/W
R/W
R
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
8
Submit Documentation Feedback
Copyright © 2013, Texas Instruments Incorporated