English
Language : 

BQ27510-G3 Datasheet, PDF (4/20 Pages) Texas Instruments – System-Side Impedance Track Fuel Gauge With Direct Battery Connection
bq27510-G3
SLUSAT1 – MARCH 2013
RECOMMENDED OPERATING CONDITIONS (continued)
TA = 25°C, VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITION
VA3
tPUCD
TA
Input voltage range (SRP, SRN)
Power-up communication delay
Operating free-air temperature range
www.ti.com
MIN
VSS–0.125
–40
TYP
250
MAX
0.125
85
UNIT
V
ms
°C
2.5 V LDO (1)
TA = 25°C, CREG = 0.47 μF, VREGIN = 3.6 V (unless otherwise noted)
PARAMETER
TEST CONDITION
VREG25
VDO
ΔVREGTEMP
Regulator output voltage
Regulator dropout voltage
Regulator output change
with temperature
2.7 V ≤ VREGIN ≤ 5.5 V,
IOUT ≤ 16mA
2.45 V ≤ VREGIN < 2.7 V (low
battery), IOUT ≤ 3mA
2.7 V, IOUT ≤ 16 mA
2.45 V, IOUT ≤ 3 mA
VREGIN = 3.6 V, IOUT = 16 mA
TA = –40°C to 85°C
TA = –40°C to 85°C
TA = –40°C to 85°C
TA = –40°C to 85°C
ΔVREGLINE
ΔVREGLOAD
ISHORT (2)
Line regulation
Load regulation
Short circuit current limit
2.7 V ≤ VREGIN ≤ 5.5 V, IOUT = 16 mA
0.2 mA ≤ IO UT ≤ 3 mA, VREGIN = 2.45 V
3 mA ≤ IOUT ≤ 16 mA, VREGIN = 2.7 V
VREG25 = 0 V
TA = –40°C to 85°C
(1) LDO output current, IOUT, is the sum of internal and external load currents.
(2) Assured by design. Not production tested.
POWER-ON RESET
TA = –40°C to 85°C, typical values at TA = 25°C and VBAT = 3.6 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
VIT+
VHYS
Positive-going battery voltage input at VCC
Power-on reset hysteresis
MIN NOM MAX UNIT
2.4 2.5 2.6 V
2.40
V
280 mV
50
0.3%
11
25 mV
34
40 mV
31
250 mA
MIN TYP MAX UNIT
2.05 2.20 2.31 V
45 115 185 mV
INTERNAL TEMPERATURE SENSOR CHARACTERISTICS
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX
GTEMP
Temperature sensor voltage gain
–2
UNIT
mV/°C
INTERNAL CLOCK OSCILLATORS
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP MAX
fOSC
fLOSC
High Frequency Oscillator
Low Frequency Oscillator
8.389
32.768
UNIT
MHz
kHz
INTEGRATING ADC (COULOMB COUNTER) CHARACTERISTICS
TA = –40°C to 85°C, 2.4 V < VCC < 2.6 V; typical values at TA = 25°C and VCC = 2.5 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP MAX
VSR_IN
tSR_CONV
Input voltage range, V(SRN) and V(SRP)
Conversion time
Resolution
VSR = V(SRN) – V(SRP)
Single conversion
–0.125
14
0.125
1
15
VSR_OS
INL
Input offset
Integral nonlinearity error
10
±0.007 ±0.034
UNIT
V
s
bits
μV
%FSR
4
Submit Documentation Feedback
Copyright © 2013, Texas Instruments Incorporated