English
Language : 

TCM29C13A Datasheet, PDF (7/25 Pages) Texas Instruments – COMBINED SINGLE-CHIP PCM CODEC AND FILTER
TCM29C13A, TCM29C14A, TCM29C16A, TCM29C17A,
TCM129C13A, TC,129C14A, TCM129C16A, TCM129C17A
COMBINED SINGLE-CHIP PCM CODEC AND FILTER
SCTS030E – AUGUST 1989 – REVISED OCTOBER 1996
gain and dynamic range, VCC = 5 V, VBB = 5 V, TA = 25°C (see Notes 4, 5, and 6)
(unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP MAX UNIT
Encoder milliwatt response (transmit gain tolerance)
Signal input = 1.064 Vrms for µ-law,
Signal input = 1.068 Vrms for A-law
± 0.04 ± 0.2 dBm0
Encoder milliwatt response (nominal supplies and temperature)
Digital milliwatt response (receive tolerance gain) relative to
zero-transmission level point
TA = 0°C to 70°C, Supplies = ± 5%
Signal input per CCITT G.711,
Output signal = 1 kHz
± 0.08 dB
± 0.04 ± 0.2 dBm0
Digital milliwatt response variation with temperature and supplies
µ-law
A-law
Zero-transmission-level point, transmit channel (0 dBm0)
µ-law
A-law
TA = 0°C to 70°C, Supplies = ± 5%
RL = 600 Ω
RL = 900 Ω
± 0.08
2.76
2.79
1
1.03
dB
dBm
Zero-transmission-level point, receive channel (0 dBm0)
µ-law
A-law
µ-law
A-law
RL = 600 Ω
RL = 900 Ω
5.76
5.79
dBm
4
4.03
NOTES: 4. Unless otherwise noted, the analog input is a 0-dBm0, 1020-Hz sine wave, where 0 dBm0 is defined as the zero-reference point of
the channel under test. This corresponds to an analog signal input of 1.064 Vrms or an output of 1.503 Vrms.
5. The input amplifier is set for noninverting unity gain. The digital input is a PCM bit stream generated by passing a 0-dBm0, 1020-Hz
sine wave through an ideal encoder.
6. Receive output is measured single ended in the maximum-gain configuration. To set the output amplifier for maximum gain, GSR is
connected to PWRO – and the output is taken at PWRO +. All output levels are (sin x)/x corrected.
gain tracking over recommended ranges of supply voltage and operating free-air temperature,
reference level = –10 dBm0
PARAMETER
Transmit gain-tracking error, sinusoidal input
Receive gain-tracking error, sinusoidal input
TEST CONDITIONS
3 ≥ input level ≥ – 40 dBm0
– 40 > input level ≥ – 50 dBm0
– 50 > input level ≥ – 55 dBm0
3 ≥ input level ≥ – 40 dBm0
– 40 > input level ≥ – 50 dBm0
– 50 > input level ≥ – 55 dBm0
MIN MAX
± 0.25
± 0.5
± 1.2
± 0.25
± 0.5
± 1.2
UNIT
dB
dB
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
7