English
Language : 

TC246CYM-B0 Datasheet, PDF (7/27 Pages) Texas Instruments – 680 x 500 PIXEL IMPACTRONTM COMPLEMENTARY COLOR CCD IMAGE SENSOR
TC246CYM-B0
680 x 500 PIXEL IMPACTRONTM COMPLEMENTARY COLOR CCD IMAGE SENSOR
SOCS089 – MAY 2005
Absolute maximum ratings over operating free-air temperature range
(unless otherwise noted)*
Supply voltage range, Vss: VDD, VCLD (see Note1)
Supply voltage range, Vss: ODB
Input voltage range, Vi: IAG1, SAG1, SAG2
Input voltage range, Vi: IAG2
Input voltage range, Vi: SRG1, SRG2, RST
Input voltage range, Vi: CMG
Supply voltage range, Vcool: P+ (see Note2)
Supply current range, Icool: P+ (see Note2)
Supply current range, Ith: THER
Operating free-air temperature range, Ta
Storage temperature range, Tstg
Dew point inside the package (see Note2)
0V to 15V
0V to 22V
- 10V to 10V
- 10V to 13V
0V to 10V
-5V to 22V
0V to 5.5V
0A to 1.4A
0A to 0.31mA
-20°C to 55°C
-30°C to 85°C
Less than -20°C
* Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the
device. These are stress ratings only, and functional operation of the device at these or any other
conditions beyond those indicated under “recommended operating conditions” is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect the device reliability.
Notes:
1.
2.
All voltage values are with respect to substrate terminal.
The Peltier cooler generates heat during cooling process. Heat must be removed through
an external heat sink. In order to avoid condensation upon the surface do not cool the CCD to less
than -20 degrees C.
7
TEXAS
INSTRUMENTS
POST OFFICE BOX 655303 * DALLAS TEXAS 75265