English
Language : 

BQ2013H Datasheet, PDF (7/24 Pages) Texas Instruments – Gas Gauge IC for Power- Assist Applications
PROG4
H
Z
L
bq2013H
Table 4. Programmed Display Mode
Overload Threshold
VOVLD = -75mV
VOVLD = -75mV
VOVLD = -25mV
Display Mode
Relative/4s timer after push-button release
Relative/4s timer after push-button release
Absolute/4s timer after push-button release
PROG5
H
Z
L
Table 5. Programmed Charge Compensation
<30°C
0.80
1.00
0.85
Trickle
30°C—50°C
0.75
1.00
0.80
>50°C
0.70
1.00
0.75
<30°C
0.95
1.00
0.95
Fast
30°C—50°C
0.90
1.00
0.90
>50°C
0.85
1.00
0.85
Table 6. Programmed Discharge Offset Adjustment
PROG6
H
Z
L
Offset
-150µV
-75µV
0µV
7