recommended operating conditions (see Note 3)
VCC Supply voltage
VIH
High-level input voltage
VIL
Low-level input voltage
VI
Input voltage
IOH
High-level output current
IOL
Low-level output current
TA
Operating free-air temperature
NOTE 3: Unused inputs must be held high or low.
MIN MAX UNIT
3 3.6 V
2
V
0.8 V
0 5.5 V
– 32 mA
32 mA
0
70 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TA = 25°C
MIN MAX
VIK
VOH
VOL
II
IOZH
IOZL
ICC
VCC = 3 V,
VCC = MIN to MAX†,
VCC = 3 V,
VCC = 3 V
VCC = 0 or MAX†,
VCC = 3.6 V,
VCC = 3.6 V,
VCC = 3.6 V,
VCC = 3.6 V,
VI = VCC or GND
II = –18 mA
IOH = – 100 µA
IOH = – 32 mA
IOL = 100 µA
IOL = 32 mA
VI = 3.6 V
VI = VCC or GND
VO = 3 V
VO = 0
IO = 0,
Outputs high
Outputs low
Outputs disabled
–1.2
VCC – 0.2
2
0.2
0.5
±10
±1
10
– 10
1
1
1
Ci
VI = VCC or GND
4
Co
VO = VCC or GND
8
† For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
UNIT
V
V
V
µA
µA
µA
mA
pF
pF
6
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265