English
Language : 

CD74ACT297 Datasheet, PDF (6/12 Pages) Texas Instruments – DIGITAL PHASE-LOCKED LOOP
CD74ACT297
DIGITAL PHASE-LOCKED LOOP
SCHS297A – AUGUST 1998 – REVISED SEPTEMBER 1999
Mfc
fout, φout
K CLK
D/U
ENCTR
XORPD OUT
φA1
φB
Divide-By-K
Counter
Carry
Borrow
fin, φin
J
ECPD
φA2
K
I/D OUT
I/D CLK
I/D Circuit
2 Nfc
Divide-By-N
Counter
Figure 3. DPLL Using Both Phase Detectors in a Ripple-Cancellation Scheme
absolute maximum ratings over recommended operating free-air temperature range (unless
otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.5 V to 6 V
DC input diode current, IIK (VI < –0.5 V or VI > VCC + 0.5 V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±20 mA
DC input diode current, IOK (VO < –0.5 V or VO > VCC + 0.5 V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±50 mA
DC output source or sink current per output pin, IO (VO > –0.5 V or VO < VCC + 0.5 V) . . . . . . . . . . ±50 mA
Continuous current through VCC or GND (Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±100 mA
Package thermal impedance,θJA (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73°C/W
Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. For up to four outputs per device, add ±25 mA for each additional output.
2. The package thermal impedance is calculated in accordance with JESD 51.
recommended operating conditions
VCC
VIH
VIL
VI
VO
dt/dv
TA
Supply voltage
High-level input voltage
Low-level input voltage
Input voltage
Output voltage
Input rise and fall slew rate
Operating free-air temperature range
MIN MAX UNIT
4.5 5.5 V
2
V
0.8 V
0 VCC V
0 VCC V
10 ns
–40
85 °C
6
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265