CC2543 Datasheet, PDF (6/29 Pages) Texas Instruments – System-on-Chip for 2.4-GHz RF Applications
CC2543
SWRS107B – APRIL 2012 – REVISED MAY 2012
www.ti.com
RF TRANSMIT SECTION
Measured on Texas Instruments CC2543EM reference design with TA = 25°C, VDD = 3 V, and fC = 2440 MHz, unless
otherwise noted.
PARAMETER
TEST CONDITIONS
MIN
TYP MAX UNIT
Output power, maximum setting
Delivered to a single-ended 50-Ω load through a balun using
maximum recommended output power setting.
5
dBm
Output power, minimum setting
Delivered to a single-ended 50-Ω load through a balun using
minimum recommended output power setting.
–20
dBm
Programmable output power range Delivered to a single-ended 50-Ω load through a balun.
25
dB
f < 1 GHz
–46
dBm
Spurious emission in TX.
Conducted measurement
f > 1 GHz
–46
dBm
Suitable for Systems Targeting Compliance With Worldwide Radio Frequency Regulations: ETSI EN
300 328 and EN 300 440 Class 2 (Europe), FCC CFR47 Part 15 (US), and ARIB STD-T66 (Japan)
Use a simple LC filter (1.6nH and 1.8pF in parallel to ground) to pass ETSI conducted requirements below 1GHz
in restricted bands. For radiated measurements low antenna gain for these frequencies (depending on antenna
design) can achieve the same attenuation of these low frequency components (see EM reference design).
32-MHz CRYSTAL OSCILLATOR
Measured on Texas Instruments CC2543EM reference design with TA = 25°C, VDD = 3 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
MIN
TYP MAX
Crystal frequency
32
Crystal frequency accuracy
requirement
250 kbps and 500 kbps data rates
1 Mbps data rate
2 Mbps data rate
–30
30
–40
40
–60
60
Equivalent series resistance
6
60
Crystal shunt capacitance
1
7
Crystal load capacitance
10
16
Start-up time
0.25
Power-down guard time
The crystal oscillator must be in power down for a guard time
before it is used again. This requirement is valid for all modes of
operation. The need for power-down guard time can vary with
3
crystal type and load.
UNIT
MHz
ppm
Ω
pF
pF
ms
ms
32-kHz RC OSCILLATOR
Measured on Texas Instruments CC2543EM reference design with TA = 25°C, VDD = 3 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
MIN TYP MAX
Calibrated frequency
32.753
Frequency accuracy after calibration
±0.2%
Temperature coefficient
0.4
Supply-voltage coefficient
3
Calibration time
2
UNIT
kHz
%/ºC
%/V
ms
16-MHz RC OSCILLATOR
Measured on Texas Instruments CC2543EM reference design with TA = 25°C, VDD = 3 V, unless otherwise noted.
PARAMETER
TEST CONDITIONS
MIN TYP MAX
Calibrated frequency
16
Uncalibrated frequency accuracy
±18%
Frequency accuracy after calibration
±0.6%
Start-up time
10
Initial calibration time
50
UNIT
MHz
µs
µs
6
Submit Documentation Feedback
Product Folder Link(s) :CC2543
Copyright © 2012, Texas Instruments Incorporated