English
Language : 

BQ24152 Datasheet, PDF (6/38 Pages) Texas Instruments – Fully Integrated Switch-Mode One-Cell Li-Ion Charger with Full USB Compliance and USB-OTG Support
bq24152
SLUS847 – JUNE 2008 ...................................................................................................................................................................................................... www.ti.com
ELECTRICAL CHARACTERISTICS (continued)
Circuit of Figure 1, VBUS = 5 V, HZ_MODE = 0, OPA_MODE = 0 (charger mode operation), TJ = 0°C to 125°C, TJ = 25°C for
typical values (unless otherwise noted)
PARAMETER
TEST CONDITIONS
BOOST MODE OPERATION FOR VBUS (OPA_MODE = 1, HZ_MODE = 0)
V(BUS_B)
Boost output voltage (to pin
VBUS)
2.5 V < V(AUXPWR) < 4.5 V, Open loop
Boost output voltage accuracy Including line and load regulation
I(BO)
Maximum output current for
boost
V(BUS_B) = 5.05 V, 2.5 V < V(AUXPWR) < 4.5 V
I(BLIMIT)
Cycle by cycle current limit for
boost
V(BUS_B) = 5.05 V, 2.5 V < V(AUXPWR) < 4.5 V
VBUS(OVP)
V(BAT)MAX
V(BAT)MIN
Overvoltage protection threshold
for boost (VBUS pin)
VBUS(OVP) hysteresis
Maximum battery voltage for
boost (CSOUT pin)
V(BAT)MAX hysteresis
Minimum battery voltage for
boost (AUXPWR pin)
Threshold over VBUS to turn off converter during
boost
VBUS falling from above VBUS(OVP)
V(CSOUT) rising edge during boost
V(CSOUT) falling from above VBATMAX
During boosting
Before boost starts
Boost output resistance at
high-impedance mode (From
VBUS to PGND)
HZ_MODE = 1
PROTECTION
V(OVP-IN)
V(OVP)
I(LIMIT)
Input VBUS OVP threshold
voltage
V(OVP_IN) hysteresis
Battery OVP threshold voltage
V(OVP) hysteresis
Cycle-by-cycle current limit for
charge
Threshold over VBUS to turn off converter during
charge
VBUS falling from above V(OVP_IN)
V(CSOUT) threshold over V(OREG) to turn off charger
during charge
Lower limit for V(CSOUT) falling from above V(OVP)
Charge mode operation
V(SHORT)
I(SHORT)
T(SHTDWN)
Short-circuit voltage threshold
V(SHORT) hysteresis
Short-circuit current
Thermal trip
Thermal hysteresis
V(AUXPWR) falling
V(AUXPWR) rising from below V(SHORT)
V(AUXPWR) ≤ V(SHORT)
T(CF)
T(32S)
Thermal regulation threshold(3)
Time constant for the 32 second
timer
Charge current begins to reduce
32 Second mode
MIN
200
5.8
4.75
165
6.3
110
1.5
1.9
5
12
TYP
5.05
±3%
1
6
125
4.9
200
2.5
2.9
MAX UNIT
V
mA
A
6.2 V
mV
5.05 V
mV
V
3.05 V
kΩ
6.5
6.7 V
140
mV
117
121 %V(ORE
11
G)
2.3
3A
2
2.1 V
100
mV
10
15 mA
165
10
°C
120
32
s
(3) Verified by design
6
Submit Documentation Feedback
Product Folder Link(s): bq24152
Copyright © 2008, Texas Instruments Incorporated