English
Language : 

TLC5952 Datasheet, PDF (5/33 Pages) Texas Instruments – 24-Channel, Constant-Current LED Driver with Global Brightness Control and LED Open-Short Detection
TLC5952
www.ti.com........................................................................................................................................................................................................ SBVS129 – MAY 2009
ELECTRICAL CHARACTERISTICS (continued)
At TA = –40°C to +85°C, VCC = 3 V to 5.5 V, and VLED = 5 V, unless otherwise noted. Typical values are at TA = +25°C and
VCC = 3.3 V.
TLC5952
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX UNIT
ΔIOLC2 Line regulation(3)
ΔIOLC3 Load regulation(4)
TTEF
Thermal error flag
threshold
At OUTR0-OUTR7, OUTG0-OUTG7, and OUTB0-OUTB7,
All OUTRn/Gn/Bn = on, BCR/G/B = 7Fh,
VOUTRn/Gn/Bn = VOUTfix = 1 V, RIREF = 1.5 kΩ
At OUTR0-OUTR7, OUTG0-OUTG7, and OUTB0-OUTB7,
All OUTRn/Gn/Bn = on, BCR/G/B = 7Fh,
VOUTRn/Gn/Bn = 1 V to 3 V, VOUTfix = 1 V, RIREF = 1.5 kΩ
Junction temperature(5)
+150
±0.5
±1
+165
±1 %
±3 %/V
+180 °C
THYS
Thermal error flag
hysteresis
Junction temperature(5)
5
10
20 °C
VLOD0
VLOD1
VLOD2
VLOD3
VLSD0
VLSD1
VLSD2
VLSD3
VIREF
All OUTRn/Gn/Bn = on, detection voltage select code = 0h
LED open detection
threshold
All OUTRn/Gn/Bn = on, detection voltage select code = 1h
All OUTRn/Gn/Bn = on, detection voltage select code = 2h
All OUTRn/Gn/Bn = on, detection voltage select code = 3h
All OUTRn/Gn/Bn = on, detection voltage select code = 4h
LED short detection
threshold
All OUTRn/Gn/Bn = on, detection voltage select code = 5h
All OUTRn/Gn/Bn = on, detection voltage select code = 6h
All OUTRn/Gn/Bn = on, detection voltage select code = 7h
Reference voltage output RIREF = 1.5 kΩ
0.25
0.30
0.35 V
0.50
0.60
0.70 V
0.80
0.90
1.00 V
1.10
1.20
1.30 V
0.55 × VCC
0.60 × VCC
0.65 × VCC
V
0.65 × VCC
0.70 × VCC
0.75 × VCC
V
0.75 × VCC
0.80 × VCC
0.85 × VCC
V
0.85 × VCC
0.90 × VCC
0.95 × VCC
V
1.17
1.20
1.23 V
(3) Line regulation is calculated by the following equation (X = R, G, or B; n = 0-7):
D (%/V) =
(IOUTXn at VCC = 5.5 V) - (IOUTXn at VCC = 3.0 V)
(IOUTXn at VCC = 3.0 V)
100
´
5.5 V - 3 V
(4) Load regulation is calculated by the following equation (X = R, G, or B; n = 0-7):
D (%/V) =
(IOUTXn at VOUTXn = 3 V) - (IOUTXn at VOUTXn = 1 V)
(IOUTXn at VOUTXn = 1 V)
100
´
3V-1V
(5) Not tested; specified by design.
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): TLC5952
Submit Documentation Feedback
5