English
Language : 

TL494_15 Datasheet, PDF (5/33 Pages) Unisonic Technologies – VOLTAGE MODE PWM CONTROL CIRCUIT
www.ti.com
TL494
SLVS074G – JANUARY 1983 – REVISED JANUARY 2015
7.5 Electrical Characteristics, Reference Section
over recommended operating free-air temperature range, VCC = 15 V, f = 10 kHz (unless otherwise noted)
PARAMETER
TEST CONDITIONS(1)
TL494C, TL494I
MIN TYP(2) MAX
Output voltage (REF)
Input regulation
Output regulation
Output voltage change with temperature
Short-circuit output current(3)
IO = 1 mA
VCC = 7 V to 40 V
IO = 1 mA to 10 mA
ΔTA = MIN to MAX
REF = 0 V
4.75
5 5.25
2
25
1
15
2
10
25
(1) For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
(2) All typical values, except for parameter changes with temperature, are at TA = 25°C.
(3) Duration of short circuit should not exceed one second.
UNIT
V
mV
mV
mV/V
mA
7.6 Electrical Characteristics, Oscillator Section
CT = 0.01 μF, RT = 12 kΩ (see Figure 5)
PARAMETER
TEST CONDITIONS(1)
TL494C, TL494I
MIN TYP(2) MAX
Frequency
Standard deviation of frequency(3)
Frequency change with voltage
Frequency change with temperature(4)
All values of VCC, CT, RT, and TA constant
VCC = 7 V to 40 V, TA = 25°C
ΔTA = MIN to MAX
10
100
1
10
(1) For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions.
(2) All typical values, except for parameter changes with temperature, are at TA = 25°C.
(3) Standard deviation is a measure of the statistical distribution about the mean as derived from the formula:
Ã¥ ( ) N
2
xn - X
s = n=1
N-1
(4) Temperature coefficient of timing capacitor and timing resistor are not taken into account.
UNIT
kHz
Hz/kHz
Hz/kHz
Hz/kHz
7.7 Electrical Characteristics, Error-Amplifier Section
See Figure 6
PARAMETER
TEST CONDITIONS
Input offset voltage
Input offset current
Input bias current
Common-mode input voltage range
Open-loop voltage amplification
Unity-gain bandwidth
Common-mode rejection ratio
Output sink current (FEEDBACK)
Output source current (FEEDBACK)
VO (FEEDBACK) = 2.5 V
VO (FEEDBACK) = 2.5 V
VO (FEEDBACK) = 2.5 V
VCC = 7 V to 40 V
ΔVO = 3 V, VO = 0.5 V to 3.5 V, RL = 2 kΩ
VO = 0.5 V to 3.5 V, RL = 2 kΩ
ΔVO = 40 V, TA = 25°C
VID = –15 mV to –5 V, V (FEEDBACK) = 0.7 V
VID = 15 mV to 5 V, V (FEEDBACK) = 3.5 V
(1) All typical values, except for parameter changes with temperature, are at TA = 25°C.
TL494C, TL494I
MIN TYP(1)
2
25
0.2
–0.3 to VCC – 2
70
95
800
65
80
0.3 0.7
–2
MAX
10
250
1
UNIT
mV
nA
μA
V
dB
kHz
dB
mA
mA
Copyright © 1983–2015, Texas Instruments Incorporated
Product Folder Links: TL494
Submit Documentation Feedback
5