7.1 Absolute Maximum Ratings
over operating free-air temperature (unless otherwise noted) (1)(2)(3)
Power supply voltage (VM)
Charge pump and high-side gate drivers (VCP, UHSG, VHSG, WHSG)
Output terminal, low side gate drivers, charge pump flying cap and switched VM
power supply voltage (U, V, W, ULSG, VLSG, WLSG, CP1, CP2 VSW)
Internal core voltage regulator (VINT)
Linear voltage regulator output (VREG)
Sense current terminal (ISEN)
Digital terminal voltage (FAULTn, LOCKn, PWM, BRAKE, DIR, ENABLEn,
HALLOUT)
Hall sensor input terminal voltage (HU+, HU–, HV+, HV–, HW+, HW–)
Continuous total power dissipation
Operating junction temperature range, TJ
MIN
MAX
–0.3
35
–0.3
50
–0.6
40
–0.3
2.0
–0.3
5.5
–0.3
2.0
–0.5
5.75
0
VREG
See Thermal Information
–40
150
UNIT
V
V
V
V
V
V
V
V
°C
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to network ground terminal.
(3) Power dissipation and thermal limits must be observed
7.2 Handling Ratings
over operating free-air temperature range (unless otherwise noted)
PARAMETER
DEFINITION
Tstg
Storage temperature range
MIN
MAX
UNIT
–60
150
°C
7.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
VM
VMDIS
IVREG
IVSW
fHALL
fPWM
Motor power supply voltage range, ENABLEn = 0, motor operating (1)
Motor power supply voltage range, ENABLEn = 1, motor not operating
VREG output current(2)
VSW output current(2)
Hall sensor input frequency(3)
Frequency on PWM
(1) Note that at VM < 12 V, gate drive output voltage tracks VM voltage
(2) Power dissipation and thermal limits must be observed
(3) fHALL of 50 Hz to 6.7 kHz is best
(4) Operational with frequencies above 50 kHz, but resolution is degraded
MIN
NOM
MAX UNIT
8.5
32
V
4.5
35
0
30
mA
0
30
0
30 kHz
16
50 (4) kHz