ABSOLUTE MAXIMUM RATINGS(1)(2)
VALUE
UNIT
VIN
Input voltage range
–0.3 to 20
V
Voltage range on EN, STATUS, PEAK, HOLD, OSC, SENSE, KEEP
–0.3 to 7
V
Voltage range on OUT
–0.3 to 20
V
ESD rating
HBM (human body model)
2000
V
CDM (charged device model)
500
TJ
Operating virtual junction temperature range
Tstg
Storage temperature range
–40 to 125
°C
–65 to 150
°C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute–maximum–rated conditions for extended periods may affect device reliability.
(2) All voltage values are with respect to network ground terminal.
RECOMMENDED OPERATING CONDITIONS
over operating free-air temperature range (unless otherwise noted)
MIN
NOM
IQ
Supply current
VIN
Device will start sinking current when VIN > 15 V to limit VIN
CIN
Input capacitor between VIN and GND (1)
L
Solenoid inductance
1
1.5
6
15
1
4.7
1
TA
Operating ambient temperature
-40
(1) 4.7-µF input capacitor and full wave rectified 230-Vrms AC supply results in approximately 500-mV supply ripple.
MAX
3
105
UNIT
mA
V
µF
H
°C
ELECTRICAL CHARACTERISTICS
VIN = 14 V, TA = -40°C to 105°C, over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
SUPPLY
Standby current
Quiescent current
IQ
Internally regulated supply
GATE DRIVER
EN = 0, VIN = 14 V, bypass deactivated
EN = 1, VIN = 14 V, bypass deactivated
EN = 0, IVIN = 2 mA, bypass activated
EN = 1, IVIN = 2 mA, bypass activated
200
360
10.5
15
14.5
15
VDRV
Gate drive voltage
Supply voltage in regulation (IVIN > 1 mA)
IDRV_SINK
Gate drive sink current
VOUT = 15 V; VIN = 15 V
IDRV_SOURCE Gate drive source current
VOUT = GND; VIN = 15 V
fPWM
PWM clock frequency
OSC = GND
DMAX
Maximum PWM duty cycle
DMIN
Minimum PWM duty cycle
tD
Start-up delay
Delay between EN going high until gate driver
starts switching, fPWM = 20 kHz
CURRENT CONTROLLER, INTERNAL SETTINGS
VIN
8
15
-15
15
20
100
7.5
IPEAK
IHOLD
Peak current
Hold current
RSENSE = 1 Ω, PEAK = GND
RSENSE = 1 Ω, HOLD = GND
270
300
40
50
MAX UNIT
250
µA
570
19
V
15.5
V
mA
-10 mA
27 kHz
%
%
50 µs
330 mA
65 mA
Copyright © 2012, Texas Instruments Incorporated