ELECTRICAL CHARACTERISTICS (continued)
5.0V ≤ V(VCC) ≤ 28V, 0°C < TJ < +125°C, typical values are at TA = 25°C, with respect to GND (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP
MAX UNIT
RECHARGE COMPARATOR
VRECHG
Recharge threshold (with respect
to.VREG)
Recharge rising deglitch
Recharge falling deglitch
BAT OVER-VOLTAGE COMPARATOR
Measured on VFB pin
VFB decreasing below VRECHG
VFB increasing above VRECHG
35
50
10
10
65 mV
ms
ms
VOV_RISE
Over-Voltage Rising Threshold
VOV_FALL
Over-Voltage Falling Threshold
INPUT OVER-VOLTAGE COMPARATOR (ACOV)
As percentage of VFB
As percentage of VFB
104%
102%
VACOV
AC over-voltage rising threshold on
VCC
31.04
32
32.96 V
VACOV_HYS
VACOV_HYS
AC over-voltage falling hysteresis
AC over-voltage rising deglitch
AC over-voltage falling deglitch
1
V
1
ms
1
ms
THERMAL SHUTDOWN COMPARATOR
TSHUT
TSHUT_HYS
Thermal shutdown rising temperature
Thermal shutdown hysteresis
Thermal shutdown rising deglitch
Temperature increasing
Temperature increasing
145
°C
15
°C
100
ms
Thermal shutdown falling deglitch
Temperature decreasing
10
ms
THERMISTOR COMPARATOR
VLTF
VLTF_HYS
VHTF
VTCO
Cold temperature rising threshold
Rising hysteresis
Hot temperature rising threshold
Cut-off temperature rising threshold
Deglitch time for temperature out of
range detection
As percentage to VVREF
As percentage to VVREF
As percentage to VVREF
As percentage to VVREF
VTS > VLTF, or VTS < VTCO, or VTS < VHTF
72.5%
0.2%
36.2%
33.7%
73.5%
0.4%
37%
34.4%
400
74.5%
0.6%
37.8%
35.1%
ms
Deglitch time for temperature in valid
range detection
VTS < VLTF – VLTF_HYS or VTS >VTCO, or VTS > VHTF
20
ms
CHARGE OVER-CURRENT COMPARATOR (CYCLE-BY-CYCLE)
Current rising, in non-synchronous mode, mesure on
Charge over-current falling threshold
V(SRP-SRN), VSRP < 2 V
Current rising, as percentage of V(IREG_CHG), in
VOC
Charge over-current threshold floor
synchronous mode, VSRP > 2.2V
Minimum OCP threshold in synchronous mode, measure
on V(SRP-SRN), VSRP > 2.2V
Charge over-current threshold ceiling
Maximum OCP threshold in synchronous mode, measure
on V(SRP-SRN), VSRP > 2.2V
CHARGE UNDER-CURRENT COMPARATOR (CYCLE-BY-CYCLE)
45.5
mV
160%
50
mV
180
mV
VISYNSET
Charge under-current falling threshold
BATTERY SHORTED COMPARATOR (BATSHORT)
VSRP>2.2V, Switch from CCM to DCM
1
5
9 mV
VBATSHT
BAT Short falling threshold, forced
non-syn mode
VSRP falling
2
V
VBATSHT_HYS BAT short rising hysteresis
VBATSHT_DEG Deglitch on both edge
LOW CHARGE CURRENT COMPARATOR
200
mV
1
ms
VLC
Low charge current (average) falling
threshold to force into non-sync mode
Measure V(SRP-SRN)
1.25
mV
VLC_HYS
Low charge current rising hysteresis
VLC_DEG
Deglitch on both edge
VREF REGULATOR
1.25
mV
1
ms
VVREF_REG
IVREF_LIM
VREF regulator voltage
VREF current limit
VVCC > VUVLO (0 - 35mA load)
VVREF = 0 V, VVCC > VUVLO
3.267
35
3.3
3.333 V
mA
Copyright © 2010, Texas Instruments Incorporated