www.ti.com.................................................................................................................................... SLUS940A – SEPTEMBER 2009 – REVISED SEPTEMBER 2009
ELECTRICAL CHARACTERISTICS (continued)
Over junction temperature range 0°C ≤ TJ ≤ 125°C and recommended supply voltage (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
RECHARGE OR REFRESH
VRCH
Recharge detection threshold –
Normal Temp
Recharge detection threshold – Hot
Temp
VIN = 5V, VTS = 0.5V, VOUT: 4.25V → VRCH
VIN = 5V, VTS = 0.2V, VOUT: 4.15V → VRCH
VO(REG)-
0.120
VO_HT(REG)
-0.130
VO(REG
-0.095
VO_HT(REG)
-0.105
VO(REG)-
0.070
VO_HT(REG)
-0.080
tDGL1(RCH)
Deglitch time, recharge threshold
detected
VIN = 5V, VTS = 0.5V, VOUT: 4.25V → 3.5V in 1μs;
tDGL1(RCH) is time to ISET ramp
tDGL2(RCH)
Deglitch time, recharge threshold
detected in OUT-Detect Mode
VIN = 5V, VTS = 0.5V, VOUT = 3.5V inserted;
tDGL2(RCH) is time to ISET ramp
BATTERY DETECT ROUTINE (NOTE: In Hot Mode VO(REG) becomes VO_HT(REG))
VREG-BD
VOUT Reduced regulation during
battery detect
29
3.6
VO(REG)-
0.450
VO(REG
-0.400
VO(REG)-
0.350
IBD-SINK
tDGL(HI/LOW
REG)
VBD-HI
Sink current during VREG-BD
Regulation time at VREG or VREG-BD
High battery detection threshold
VIN = 5V, VTS = 0.5V, Battery Absent
VIN = 5V, VTS = 0.5V, Battery Absent
7
VO(REG)-
0.150
25
VO(REG)-
0.100
10
VO(REG)-
0.050
VBD-LO
Low battery detection threshold
VIN = 5V, VTS = 0.5V, Battery Absent
VREG-BD
+0.050
VREG-BD
+0.100
VREG-BD
+0.150
BATTERY CHARGING TIMERS AND FAULT TIMERS
tPRECHG
Pre-charge safety timer value
Restarts when entering Pre-charge; Always
enabled when in pre-charge.
1700
1940
2250
tMAXCH
Charge safety timer value
Clears fault or resets at UVLO, TS ("CE") disable,
OUT Short, exiting LOWV and Refresh
34000
38800
45000
BATTERY-PACK NTC MONITOR (Note 1); TS pin: bq24050/5: 10k NTC; bq24052: 100k NTC; See TS section for thermistor information
INTC-10k
NTC bias current; 10k NTC
thermsistor, bq24050/5
VTS = 0.3V
48
50
52
INTC-100k
NTC bias current; 100k NTC
thermsistor, bq24052
VTS = 0.3V
4.8
5
5.2
INTC-DIS-10k
bq24050/5 bias current when
Charging is disabled.
VTS = 0V
27
30
34
INTC-DIS-100k
bq24052 bias current when Charging
is disabled.
VTS = 0V
4.4
5
5.8
INTC-FLDBK-10k
INTC is reduced prior to entering
TTDM to keep cold thermistor from
entering TTDM, bq24050/5
VTS: Set to 1.525V
4
5
6.5
INTC is reduced prior to entering
INTC-FLDBK-100k TTDM to keep cold thermistor from
entering TTDM, bq24052
VTS: Set to 1.525V
1.1
1.5
1.9
VTTDM(TS)
Termination and timer disable mode
Threshold – Enter
VTS: 0.5V → 1.7V; Timer Held in Reset
1550
1600
1650
VHYS-TTDM(TS)
VCLAMP(TS)
tDGL(TTDM)
Hysteresis exiting TTDM
TS maximum voltage clamp
Deglitch exit TTDM between states
Deglitch enter TTDM between states
VTS: 1.7V → 0.5V; Timer Enabled
VTS= Open (Float)
1800
100
1950
57
8
2000
VTS_I-FLDBK
TS voltage where INTC is reduce to
keep thermistor from entering TTDM
INTC adjustment (90 to 10%; 45 to 6.6uA) takes
place near this spec threshold.
VTS: 1.425V → 1.525V
1475
UNIT
V
V
ms
ms
V
mA
ms
V
V
s
s
μA
μA
μA
μA
μA
μA
mV
mV
mV
ms
μs
mV
Copyright © 2009, Texas Instruments Incorporated