1.8
1.6
1.4
1.2
IOUT Internal Clamp Range
1
0.8
max
0.6
ISET Short
0.4
Fault
Range
0.2
min
IOUT Programmed
Non Restricted
Operating Area
0
100
1000
ISET - W
10000
Figure 27. PROGRAMMED / CLAMPED OUT CURRENT
PRE_TERM – Pre-Charge and Termination Programmable Threshold
Pre-Term is used to program both the pre-charge current and the termination current threshold, on the
bq24050/2/5. The pre-charge current level is a factor of two higher than the termination current level. The
termination can be set between 5 and 50% of the programmed output current level set by ISET. If left floating the
termination and pre-charge are set internally at 10/20% respectively. The pre-charge-to-fast-charge, Vlowv
threshold is set to 2.5V.
RPRE-TERM = %Term × KTERM = %Pre-CHG × KPRE-CHG
(0)
Where:
%Term is the percent of fast charge current where termination occurs;
%Pre-CHG is the percent of fast charge current that is desired during precharge;
KTERM and KPRE-CHG are gain factors found in the electrical specifications.
22
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated
Product Folder Link(s): bq24050 bq24052 bq24055